{"title":"External Quality Assessment of Sputum Smear Microscopy in Tuberculosis Laboratories in Sughd, Tajikistan.","authors":"Eva Chang,&nbsp;Fabio Luelmo,&nbsp;Zamira Baydulloeva,&nbsp;Marija Joncevska,&nbsp;Guljamol Kasymova,&nbsp;Oktam Bobokhojaev,&nbsp;Tom Mohr","doi":"10.5195/cajgh.2015.230","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Tajikistan has a laboratory network with three levels of tuberculosis (TB) laboratories. The external quality assessment (EQA) of sputum smear microscopy was implemented in 2007. The objective of this study was to evaluate the EQA system and identify potential performance improvement strategies in TB microscopic laboratories in Sughd, Tajikistan.</p><p><strong>Methods: </strong>This is a cross-sectional study based on retrospective record review and secondary data analyses on Acid-Fast Bacilli (AFB) microscopy data and EQA reading results collected between the first quarter of 2011 and the fourth quarter of 2013. Descriptive analyses were conducted to examine the overview of microscopy laboratories activities, EQA results, and laboratory performance.</p><p><strong>Result: </strong>Of the 123,874 smears examined between 2011 and 2013, 11,522 (9.30%) were re-checked by the EQA system. The population TB screening rate rose from 0.46% in 2011 to 0.57% in 2013, and the case positivity rate decreased from 6.98% to 4.80%. The regional EQA results showed a reduction in high false-positive, high false-negative, and low false-negative errors. False-positive errors had decreased from 0.13% in 2011 to 0.07% in 2013, and false-negative errors from 0.91% in 2011 to 0.15% in 2013. Regional sensitivity of smear microscopy, when compared to re-checking controller, increased from 88.2% in 2011 to 97.2% in 2013. The regional specificity level remained relatively stable at above 99%.</p><p><strong>Conclusion: </strong>Our study found that a decreasing trend of case positivity rate from 2011 to 2013 in Sughd, though the overall laboratory workload was on the rise. In addition, EQA results showed an overall error reduction and an improved sensitivity of smear microscopy in the region. The overview of microscopic laboratory activities and the actual evaluation of the EQA system on sputum smear microscopy complement each other in providing a better picture on the progress of TB laboratory strengthening. We recommend similar approaches to be adapted by future evaluations on TB microscopic laboratories, particularly among countries of high burden. Interactive training and feedback loops are crucial to improving TB surveillance in Tajikistan.</p>","PeriodicalId":42537,"journal":{"name":"Central Asian Journal of Global Health","volume":"4 2","pages":"230"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5661208/pdf/","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Central Asian Journal of Global Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5195/cajgh.2015.230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Introduction: Tajikistan has a laboratory network with three levels of tuberculosis (TB) laboratories. The external quality assessment (EQA) of sputum smear microscopy was implemented in 2007. The objective of this study was to evaluate the EQA system and identify potential performance improvement strategies in TB microscopic laboratories in Sughd, Tajikistan.

Methods: This is a cross-sectional study based on retrospective record review and secondary data analyses on Acid-Fast Bacilli (AFB) microscopy data and EQA reading results collected between the first quarter of 2011 and the fourth quarter of 2013. Descriptive analyses were conducted to examine the overview of microscopy laboratories activities, EQA results, and laboratory performance.

Result: Of the 123,874 smears examined between 2011 and 2013, 11,522 (9.30%) were re-checked by the EQA system. The population TB screening rate rose from 0.46% in 2011 to 0.57% in 2013, and the case positivity rate decreased from 6.98% to 4.80%. The regional EQA results showed a reduction in high false-positive, high false-negative, and low false-negative errors. False-positive errors had decreased from 0.13% in 2011 to 0.07% in 2013, and false-negative errors from 0.91% in 2011 to 0.15% in 2013. Regional sensitivity of smear microscopy, when compared to re-checking controller, increased from 88.2% in 2011 to 97.2% in 2013. The regional specificity level remained relatively stable at above 99%.

Conclusion: Our study found that a decreasing trend of case positivity rate from 2011 to 2013 in Sughd, though the overall laboratory workload was on the rise. In addition, EQA results showed an overall error reduction and an improved sensitivity of smear microscopy in the region. The overview of microscopic laboratory activities and the actual evaluation of the EQA system on sputum smear microscopy complement each other in providing a better picture on the progress of TB laboratory strengthening. We recommend similar approaches to be adapted by future evaluations on TB microscopic laboratories, particularly among countries of high burden. Interactive training and feedback loops are crucial to improving TB surveillance in Tajikistan.

Abstract Image

塔吉克斯坦苏格德肺结核实验室痰涂片镜检的外部质量评价。
导言:塔吉克斯坦有一个由三级结核病实验室组成的实验室网络。2007年实施了痰涂片镜检的外部质量评价(EQA)。本研究的目的是评估塔吉克斯坦Sughd结核病显微实验室的EQA系统并确定潜在的绩效改进策略。方法:本研究是基于2011年第一季度至2013年第四季度收集的抗酸杆菌(AFB)显微镜数据和EQA读数结果的回顾性记录回顾和二次数据分析的横断面研究。描述性分析被用于检查显微镜实验室活动、EQA结果和实验室性能的概述。结果:在2011年至2013年期间检查的123,874份涂片中,11,522份(9.30%)通过EQA系统重新检查。人群结核病筛查率由2011年的0.46%上升到2013年的0.57%,病例阳性率由6.98%下降到4.80%。区域EQA结果显示高假阳性、高假阴性和低假阴性错误的减少。假阳性错误率从2011年的0.13%下降到2013年的0.07%,假阴性错误率从2011年的0.91%下降到2013年的0.15%。与复核控制器相比,涂片镜检的区域灵敏度从2011年的88.2%上升到2013年的97.2%。区域特异性水平相对稳定在99%以上。结论:我们的研究发现,2011 - 2013年苏隆德的病例阳性率呈下降趋势,但总体实验室工作量呈上升趋势。此外,EQA结果显示,在该地区,涂片显微镜的总体误差减少和灵敏度提高。显微镜实验室活动的概述和痰涂片显微镜EQA系统的实际评价相辅相成,可以更好地了解结核病实验室加强的进展情况。我们建议在今后对结核病显微实验室的评估中采用类似的方法,特别是在高负担国家。互动式培训和反馈循环对于改善塔吉克斯坦的结核病监测至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Central Asian Journal of Global Health
Central Asian Journal of Global Health PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信