Evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T1.

Evidence-Based Medicine Pub Date : 2017-12-01 Epub Date: 2017-11-17 DOI:10.1136/ebmed-2017-110830
Jaspreet Kaur Khaira
{"title":"Evaluation of a 0-hour/1-hour algorithm in the diagnosis of myocardial infarction with high-sensitivity cardiac troponin T1.","authors":"Jaspreet Kaur Khaira","doi":"10.1136/ebmed-2017-110830","DOIUrl":null,"url":null,"abstract":"Using a highly sensitive assay of serum troponin T in patients with suspected myocardial infarction might help in early diagnosis, but the method needs thorough clinical assessment before implementation.\n\n### Summary box\n\nThe High Sensitivity Cardiac Troponin T Assay for Rapid Rule-out of Acute Myocardial Infarction trial was a prospective, multicentre, diagnostic study done at 12 sites, across three continents to validate the diagnostic accuracy of the troponin T 0-hour/1-hour algorithm for rule-in and rule-out of acute myocardial infarction.1 \n\nCurrent troponin assays for the diagnosis of myocardial infarction usually require serial sampling between 8 and 24 hours, depending on the specific assay/local protocols. This time interval contributes to ‘rule-in’ delays, delaying treatment, and ‘rule-out’ delays, costing time, …","PeriodicalId":12182,"journal":{"name":"Evidence-Based Medicine","volume":" ","pages":"235-236"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1136/ebmed-2017-110830","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Evidence-Based Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/ebmed-2017-110830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/11/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Using a highly sensitive assay of serum troponin T in patients with suspected myocardial infarction might help in early diagnosis, but the method needs thorough clinical assessment before implementation. ### Summary box The High Sensitivity Cardiac Troponin T Assay for Rapid Rule-out of Acute Myocardial Infarction trial was a prospective, multicentre, diagnostic study done at 12 sites, across three continents to validate the diagnostic accuracy of the troponin T 0-hour/1-hour algorithm for rule-in and rule-out of acute myocardial infarction.1 Current troponin assays for the diagnosis of myocardial infarction usually require serial sampling between 8 and 24 hours, depending on the specific assay/local protocols. This time interval contributes to ‘rule-in’ delays, delaying treatment, and ‘rule-out’ delays, costing time, …
高灵敏度心肌肌钙蛋白T1诊断心肌梗死的0小时/1小时算法评价
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信