Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions.

Ahmad Ghahremanloo, Mahdieh Seifi, Jalil Ghanbarzade, Seyyed Mohammad Abrisham, Rashid Abdolah Javan
{"title":"Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions.","authors":"Ahmad Ghahremanloo,&nbsp;Mahdieh Seifi,&nbsp;Jalil Ghanbarzade,&nbsp;Seyyed Mohammad Abrisham,&nbsp;Rashid Abdolah Javan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS).</p><p><strong>Materials and methods: </strong>Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body) and direct and indirect techniques (six groups) were used, and seven impressions were obtained from each group (n=42). To measure the accuracy of impressions, drift, horizontal, and vertical angles of the implants, as well as the hex rotation of the implants in casts were evaluated using a digitizer device (1μm accuracy), in comparison with master arch. Data were analyzed using five-factor two-way ANOVA and Tukey's post-hoc test.</p><p><strong>Results: </strong>The accuracy of impressions was assessed and the results showed that direct technique was not significantly different from indirect technique (P>0.05). Also, there were no significant differences between the mentioned viscosities except for the horizontal angle (P=0.006).</p><p><strong>Conclusions: </strong>Viscosity of impression materials is of high significance for the accuracy of dental impressions.</p>","PeriodicalId":30286,"journal":{"name":"Journal of Dentistry of Tehran University of Medical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557995/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry of Tehran University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS).

Materials and methods: Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body) and direct and indirect techniques (six groups) were used, and seven impressions were obtained from each group (n=42). To measure the accuracy of impressions, drift, horizontal, and vertical angles of the implants, as well as the hex rotation of the implants in casts were evaluated using a digitizer device (1μm accuracy), in comparison with master arch. Data were analyzed using five-factor two-way ANOVA and Tukey's post-hoc test.

Results: The accuracy of impressions was assessed and the results showed that direct technique was not significantly different from indirect technique (P>0.05). Also, there were no significant differences between the mentioned viscosities except for the horizontal angle (P=0.006).

Conclusions: Viscosity of impression materials is of high significance for the accuracy of dental impressions.

Abstract Image

Abstract Image

Abstract Image

聚乙烯烷黏度对种植体印模精度的影响。
目的:本研究的目的是比较不同印模技术和聚氯乙烯(PVS)粘度的组合所获得的牙种植体印模的准确性。材料与方法:在下牙弓主模型的颏孔间放置4个平行固定装置。使用了三种不同粘度(腻子/轻体、中等体/轻体和单相:重体)和直接和间接技术(六组),每组获得7个印痕(n=42)。为了测量压模的精度,植入体的漂移、水平和垂直角度以及铸件中植入体的十六进制旋转都使用数字化仪设备进行评估(精度为1μm),与主弓进行比较。数据分析采用五因素双因素方差分析和Tukey事后检验。结果:对直接法和间接法的印模精度进行了评估,结果表明直接法与间接法的印模精度差异无统计学意义(P>0.05)。此外,除了水平角度外,上述粘度之间没有显著差异(P=0.006)。结论:印模材料的黏度对印模的准确性有重要影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信