Éric Heleno Freire Ferreira Frederico, Danúbia da Cunha de Sá-Caputo, Eloá Moreira-Marconi, Carlos Alberto Sampaio Guimarães, André Luiz Bandeira Dionísio Cardoso, Carla da Fontoura Dionello, Danielle Soares Morel, Cintia Renata Sousa-Gonçalves, Laisa Liana Paineiras-Domingos, Rebeca Graça Costa Cavalcanti, Nasser Ribeiro Asad, Pedro Jesus Marin, Mario Bernardo-Filho
{"title":"EFFECT OF MECHANICAL VIBRATION GENERATED IN OSCILLATING/VIBRATORY PLATFORM ON THE CONCENTRATION OF PLASMA BIOMARKERS AND ON THE WEIGHT IN RATS.","authors":"Éric Heleno Freire Ferreira Frederico,&nbsp;Danúbia da Cunha de Sá-Caputo,&nbsp;Eloá Moreira-Marconi,&nbsp;Carlos Alberto Sampaio Guimarães,&nbsp;André Luiz Bandeira Dionísio Cardoso,&nbsp;Carla da Fontoura Dionello,&nbsp;Danielle Soares Morel,&nbsp;Cintia Renata Sousa-Gonçalves,&nbsp;Laisa Liana Paineiras-Domingos,&nbsp;Rebeca Graça Costa Cavalcanti,&nbsp;Nasser Ribeiro Asad,&nbsp;Pedro Jesus Marin,&nbsp;Mario Bernardo-Filho","doi":"10.21010/ajtcam.v14i4S.7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Whole body vibration (WBV) exercise has been used in health sciences. Authors have reported that changes on the concentration of plasma biomarkers could be associated with the WBV effects. The aim of this investigation is to assess the consequences of exposition of 25 Hz mechanical vibration generated in oscillating/vibratory platform (OVP) on the concentration of some plasma biomarkers and on the weight of rats.</p><p><strong>Materials and methods: </strong><i>Wistar</i> rats were divided into two groups. The animals of the Experimental Group (EG) were submitted to vibration (25 Hz) generated in an OVP with four bouts of 30 seconds with rest time of 60 seconds between the bouts. This procedure was performed daily for 12 days. The animals of the control group (CG) were not exposed to vibration.</p><p><strong>Results: </strong>Our findings show that the WBV exercise at 25 Hz was not capable to alter significantly (<i>p</i><0.05) the weight of the rats. A significant alteration in the concentrations of amylase was found.</p><p><strong>Conclusion: </strong>Our results indicate a modulation of the WBV exercise with vibration of 25 Hz of frequency (i) in the pathways related to the weight and (ii) in the concentration of some biomarkers, such as amylase.</p>","PeriodicalId":7845,"journal":{"name":"African journal of traditional, complementary, and alternative medicines : AJTCAM","volume":"14 4 Suppl","pages":"52-58"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.21010/ajtcam.v14i4S.7","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"African journal of traditional, complementary, and alternative medicines : AJTCAM","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21010/ajtcam.v14i4S.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Whole body vibration (WBV) exercise has been used in health sciences. Authors have reported that changes on the concentration of plasma biomarkers could be associated with the WBV effects. The aim of this investigation is to assess the consequences of exposition of 25 Hz mechanical vibration generated in oscillating/vibratory platform (OVP) on the concentration of some plasma biomarkers and on the weight of rats.

Materials and methods: Wistar rats were divided into two groups. The animals of the Experimental Group (EG) were submitted to vibration (25 Hz) generated in an OVP with four bouts of 30 seconds with rest time of 60 seconds between the bouts. This procedure was performed daily for 12 days. The animals of the control group (CG) were not exposed to vibration.

Results: Our findings show that the WBV exercise at 25 Hz was not capable to alter significantly (p<0.05) the weight of the rats. A significant alteration in the concentrations of amylase was found.

Conclusion: Our results indicate a modulation of the WBV exercise with vibration of 25 Hz of frequency (i) in the pathways related to the weight and (ii) in the concentration of some biomarkers, such as amylase.

Abstract Image

振动/振动平台产生的机械振动对大鼠血浆生物标志物浓度和体重的影响。
背景:全身振动(WBV)运动已被用于健康科学。作者报道了血浆生物标志物浓度的变化可能与WBV效应有关。本研究的目的是评估在振荡/振动平台(OVP)中暴露25 Hz机械振动对一些血浆生物标志物浓度和大鼠体重的影响。材料与方法:Wistar大鼠分为两组。实验组(EG)接受OVP产生的25 Hz振动,每次30秒,每次间隔60秒。该手术每天进行12天。对照组(CG)不受振动影响。结果:我们的研究结果表明,在25赫兹的频率下,WBV运动对体重相关通路和淀粉酶等生物标志物的浓度有调节作用(1)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信