Ippei Hamanaka, Misa Iwamoto, Lippo V J Lassila, Pekka K Vallittu, Yutaka Takahashi
{"title":"Wear resistance of injection-molded thermoplastic denture base resins.","authors":"Ippei Hamanaka, Misa Iwamoto, Lippo V J Lassila, Pekka K Vallittu, Yutaka Takahashi","doi":"10.3109/23337931.2015.1135747","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective</b> This study investigated the wear resistance of injection-molded thermoplastic denture base resins using nanoindentation instrument. <b>Materials and methods</b> Six injection-molded thermoplastic denture base resins (two polyamides, two polyesters, one polycarbonate, one polymethylmethacrylate [PMMA]) and a PMMA conventional heat-polymerized denture-based polymer control were tested. Elastic modulus, hardness, wear depth, and roughness were calculated using a nanoindentation instrument. <b>Results</b> Elastic modulus and hardness of the injection-molded thermoplastic denture base resins were significantly lower than those of the PMMA conventional heat-polymerized denture-based polymer. Wear depth of polycarbonate and PMMA conventional heat-polymerized denture-based polymer were significantly higher than that of other injection-molded thermoplastic denture base resins. The roughness of injection-molded thermoplastic denture base resins was significantly more than that of PMMA conventional heat-polymerized denture-based polymer after testing. <b>Conclusions</b> Wear resistance of injection-molded thermoplastic denture base was low compared to PMMA conventional heat-polymerized denture-based polymers.</p>","PeriodicalId":6997,"journal":{"name":"Acta Biomaterialia Odontologica Scandinavica","volume":"2 1","pages":"31-37"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/23337931.2015.1135747","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Biomaterialia Odontologica Scandinavica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/23337931.2015.1135747","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/12/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20
Abstract
Objective This study investigated the wear resistance of injection-molded thermoplastic denture base resins using nanoindentation instrument. Materials and methods Six injection-molded thermoplastic denture base resins (two polyamides, two polyesters, one polycarbonate, one polymethylmethacrylate [PMMA]) and a PMMA conventional heat-polymerized denture-based polymer control were tested. Elastic modulus, hardness, wear depth, and roughness were calculated using a nanoindentation instrument. Results Elastic modulus and hardness of the injection-molded thermoplastic denture base resins were significantly lower than those of the PMMA conventional heat-polymerized denture-based polymer. Wear depth of polycarbonate and PMMA conventional heat-polymerized denture-based polymer were significantly higher than that of other injection-molded thermoplastic denture base resins. The roughness of injection-molded thermoplastic denture base resins was significantly more than that of PMMA conventional heat-polymerized denture-based polymer after testing. Conclusions Wear resistance of injection-molded thermoplastic denture base was low compared to PMMA conventional heat-polymerized denture-based polymers.