{"title":"Flexural strengths of reinforced denture base resins subjected to long-term water immersion.","authors":"Kaneyoshi Yoshida, Yutaka Takahashi, Hirono Sasaki, Ippei Hamanaka, Tomohiro Kawaguchi","doi":"10.3109/23337931.2015.1135745","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective</b> This study evaluated the flexural strengths of reinforced denture base resins subjected to long-term water immersion. <b>Materials and methods</b> Acrylic denture base resin reinforced with metal wire or glass fiber-reinforced composite (FRC), and without reinforcement were tested. Bar-shaped specimens were fabricated. Half of the specimens were stored in 37 °C distilled water for 50 hours (h), the other half were stored in 37 °C distilled water for 180 days (d) before testing. Ten specimens were fabricated per group for each reinforcement/water immersion period combination. The ultimate flexural strength and flexural strength at the proportional limit of reinforced denture base resin were tested. <b>Results</b> The 180 d bulk specimen possessed significantly lower ultimate flexural strength compared with the 50 h bulk specimen (<i>p</i> < 0.05). The ultimate flexural strength of the 50 h metal, 50 h FRC, 180 d metal and the 180 d FRC reinforcement specimens were not significantly different from each other (<i>p</i> > 0.05). The 180 d bulk specimen had a significantly lower flexural strength at the proportional limit compared to the 50 h bulk specimen. The 180 d reinforced specimens of metal and FRC were not significantly different from each of the 50 h specimens. <b>Conclusion</b> The flexural strengths of a reinforced denture base resin did not change after long-term water immersion.</p>","PeriodicalId":6997,"journal":{"name":"Acta Biomaterialia Odontologica Scandinavica","volume":"2 1","pages":"20-24"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/23337931.2015.1135745","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Biomaterialia Odontologica Scandinavica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/23337931.2015.1135745","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/12/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
Objective This study evaluated the flexural strengths of reinforced denture base resins subjected to long-term water immersion. Materials and methods Acrylic denture base resin reinforced with metal wire or glass fiber-reinforced composite (FRC), and without reinforcement were tested. Bar-shaped specimens were fabricated. Half of the specimens were stored in 37 °C distilled water for 50 hours (h), the other half were stored in 37 °C distilled water for 180 days (d) before testing. Ten specimens were fabricated per group for each reinforcement/water immersion period combination. The ultimate flexural strength and flexural strength at the proportional limit of reinforced denture base resin were tested. Results The 180 d bulk specimen possessed significantly lower ultimate flexural strength compared with the 50 h bulk specimen (p < 0.05). The ultimate flexural strength of the 50 h metal, 50 h FRC, 180 d metal and the 180 d FRC reinforcement specimens were not significantly different from each other (p > 0.05). The 180 d bulk specimen had a significantly lower flexural strength at the proportional limit compared to the 50 h bulk specimen. The 180 d reinforced specimens of metal and FRC were not significantly different from each of the 50 h specimens. Conclusion The flexural strengths of a reinforced denture base resin did not change after long-term water immersion.