Acute Rejection in 6-Antigen HLA-Matched Kidney Transplant Recipients: Risk Factors and Outcomes from the Wisconsin Allograft Recipient Database (WisARD).

Clinical transplants Pub Date : 2016-01-01
Amanda J Condon, Brad C Astor, Kimberly E Holdener, Thomas M Ellis, Arjang Djamali
{"title":"Acute Rejection in 6-Antigen HLA-Matched Kidney Transplant Recipients: Risk Factors and Outcomes from the Wisconsin Allograft Recipient Database (WisARD).","authors":"Amanda J Condon,&nbsp;Brad C Astor,&nbsp;Kimberly E Holdener,&nbsp;Thomas M Ellis,&nbsp;Arjang Djamali","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Acute rejection in human leukocyte antigen (HLA)-matched kidney transplant recipients is uncommon and the mechanisms involved are not well understood. Data from 6-antigen HLA-matched recipients transplanted between 1994 and 2014 were analyzed to identify the incidence, risk factors, and outcomes associated with biopsy-proven acute rejection (BPAR). A total of 278 HLA-matched recipients were identified, of which, 155 (55.8%) received a graft from a sibling donor. Ten patients (3.6%) experienced BPAR over a median follow-up of 10 years (0.41 cases per 100 person-years). Median time to rejection was 36.5 months (standard deviation ±56.4). Recipients who experienced rejection did not differ from those who did not in terms of age, gender, ethnicity, induction agent, panel reactive antibody, or sensitizing events. Acute cellular, antibody-mediated, and mixed rejection occurred in 5, 3, and 2 patients, respectively. The most common biopsy classification was Banff IA (n=4). Four out of 10 patients had documented nonadherence to maintenance immunosuppression. Thirty percent of HLA-matched recipients who rejected had graft loss and 10% died, compared to 30.8% graft loss and 28.4% deaths in non-rejectors (p=0.57 and 0.20, respectively). In conclusion, acute cellular and antibody-mediated rejection are infrequent in HLA-matched kidney transplant recipients. Nonadherence appears to be relatively common among those experiencing rejection. Acute rejection was not associated with higher graft loss or death. The pathogenesis of acute rejection in HLA-matched recipients remains to be determined.</p>","PeriodicalId":77074,"journal":{"name":"Clinical transplants","volume":"32 ","pages":"135-141"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical transplants","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Acute rejection in human leukocyte antigen (HLA)-matched kidney transplant recipients is uncommon and the mechanisms involved are not well understood. Data from 6-antigen HLA-matched recipients transplanted between 1994 and 2014 were analyzed to identify the incidence, risk factors, and outcomes associated with biopsy-proven acute rejection (BPAR). A total of 278 HLA-matched recipients were identified, of which, 155 (55.8%) received a graft from a sibling donor. Ten patients (3.6%) experienced BPAR over a median follow-up of 10 years (0.41 cases per 100 person-years). Median time to rejection was 36.5 months (standard deviation ±56.4). Recipients who experienced rejection did not differ from those who did not in terms of age, gender, ethnicity, induction agent, panel reactive antibody, or sensitizing events. Acute cellular, antibody-mediated, and mixed rejection occurred in 5, 3, and 2 patients, respectively. The most common biopsy classification was Banff IA (n=4). Four out of 10 patients had documented nonadherence to maintenance immunosuppression. Thirty percent of HLA-matched recipients who rejected had graft loss and 10% died, compared to 30.8% graft loss and 28.4% deaths in non-rejectors (p=0.57 and 0.20, respectively). In conclusion, acute cellular and antibody-mediated rejection are infrequent in HLA-matched kidney transplant recipients. Nonadherence appears to be relatively common among those experiencing rejection. Acute rejection was not associated with higher graft loss or death. The pathogenesis of acute rejection in HLA-matched recipients remains to be determined.

6抗原hla匹配肾移植受者的急性排斥反应:来自威斯康星同种异体移植受者数据库(WisARD)的危险因素和结果
急性排斥反应在人类白细胞抗原(HLA)匹配的肾移植受者中并不常见,其机制尚不清楚。分析1994年至2014年间6抗原hla匹配受体移植的数据,以确定与活检证实的急性排斥反应(BPAR)相关的发生率、危险因素和结果。共有278例hla匹配受体被确定,其中155例(55.8%)接受了来自兄弟姐妹供体的移植。10例患者(3.6%)在中位随访10年期间出现BPAR(每100人年0.41例)。到排斥反应的中位时间为36.5个月(标准差±56.4)。在年龄、性别、种族、诱导剂、组反应性抗体或致敏事件方面,经历过排斥反应的受者与未经历排斥反应的受者没有差异。急性细胞性、抗体介导性和混合性排斥反应分别发生在5例、3例和2例患者中。最常见的活检分类为Banff IA (n=4)。10名患者中有4名记录不坚持维持免疫抑制。30%排斥的hla匹配受体有移植物损失,10%死亡,而非排斥者的移植物损失为30.8%,28.4%死亡(p分别=0.57和0.20)。总之,急性细胞和抗体介导的排斥反应在hla匹配的肾移植受者中并不常见。在那些被拒绝的人中,不坚持似乎相对普遍。急性排斥反应与较高的移植物损失或死亡无关。hla匹配受体急性排斥反应的发病机制仍有待确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信