Detection of copy number alterations in cell-free tumor DNA from plasma

Olga Østrup , Lise Barlebo Ahlborn , Ulrik Lassen , Morten Mau-Sørensen , Finn Cilius Nielsen
{"title":"Detection of copy number alterations in cell-free tumor DNA from plasma","authors":"Olga Østrup ,&nbsp;Lise Barlebo Ahlborn ,&nbsp;Ulrik Lassen ,&nbsp;Morten Mau-Sørensen ,&nbsp;Finn Cilius Nielsen","doi":"10.1016/j.bbacli.2017.03.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Somatic copy number alterations (SCNAs) occurring in tumors can provide information about tumor classification, patient's outcome or treatment targets. Liquid biopsies, incl. plasma samples containing circulating cell-free tumor DNA (ccfDNA) can be used to assess SCNAs for clinical purposes, however specify and reliability of methods have to be tested.</p></div><div><h3>Methods</h3><p>SNP microarrays (Affymetrix) were used to generate whole-genome copy number profiles from plasma ccfDNA (OncoScan) and paired tumor biopsies (CytoScan) from ten patients with metastatic cancers. Numerical, segmental and focal SCNAs were assessed using ASCAT/TuScan and SNP-FASST2.</p></div><div><h3>Results</h3><p>Aberrations in ccfDNA in 4 patients resembled numerical (76%) and segmental (80%) aberrations in tDNA. Three patients represented low correlation due to postponed sampling time, ccfDNA quality and possible treatment interference. Breakpoints of high-amplitude amplification were assessed with high accuracy and relative breakpoints difference of only 7% (0.02–37%). Similarly, biallelic losses were reliably detected. Array was 100% successful in detection of SCNAs on clinically relevant genes compared to SCNAs in tumor biopsies. Tracking of SCNAs changes during the treatment course of one patient also indicated that apoptosis/necrosis of non-cancerous cells presumably induced by treatment can influence ccfDNA composition and introduce false-negative findings into the analysis of liquid biopsies.</p></div><div><h3>Conclusions</h3><p>Genomic alterations detected in ccfDNA from liquid biopsies by comprehensive SNP array are reliable source for information for stratification of patients for targeted treatment.</p></div><div><h3>General significance</h3><p>Clinically relevant SCNAs can be detected in ccfDNA with high resolution and can therefore serve as an alternative to tumor biopsy in defining treatment targets.</p></div>","PeriodicalId":72344,"journal":{"name":"BBA clinical","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.bbacli.2017.03.006","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BBA clinical","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214647416300617","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Background

Somatic copy number alterations (SCNAs) occurring in tumors can provide information about tumor classification, patient's outcome or treatment targets. Liquid biopsies, incl. plasma samples containing circulating cell-free tumor DNA (ccfDNA) can be used to assess SCNAs for clinical purposes, however specify and reliability of methods have to be tested.

Methods

SNP microarrays (Affymetrix) were used to generate whole-genome copy number profiles from plasma ccfDNA (OncoScan) and paired tumor biopsies (CytoScan) from ten patients with metastatic cancers. Numerical, segmental and focal SCNAs were assessed using ASCAT/TuScan and SNP-FASST2.

Results

Aberrations in ccfDNA in 4 patients resembled numerical (76%) and segmental (80%) aberrations in tDNA. Three patients represented low correlation due to postponed sampling time, ccfDNA quality and possible treatment interference. Breakpoints of high-amplitude amplification were assessed with high accuracy and relative breakpoints difference of only 7% (0.02–37%). Similarly, biallelic losses were reliably detected. Array was 100% successful in detection of SCNAs on clinically relevant genes compared to SCNAs in tumor biopsies. Tracking of SCNAs changes during the treatment course of one patient also indicated that apoptosis/necrosis of non-cancerous cells presumably induced by treatment can influence ccfDNA composition and introduce false-negative findings into the analysis of liquid biopsies.

Conclusions

Genomic alterations detected in ccfDNA from liquid biopsies by comprehensive SNP array are reliable source for information for stratification of patients for targeted treatment.

General significance

Clinically relevant SCNAs can be detected in ccfDNA with high resolution and can therefore serve as an alternative to tumor biopsy in defining treatment targets.

Abstract Image

Abstract Image

Abstract Image

血浆中无细胞肿瘤DNA拷贝数变化的检测
肿瘤中发生的体细胞拷贝数改变(SCNAs)可以提供有关肿瘤分类、患者预后或治疗靶点的信息。液体活检,包括含有循环无细胞肿瘤DNA (ccfDNA)的血浆样本,可用于评估临床目的的scna,但必须测试方法的特异性和可靠性。方法应用snp微阵列(Affymetrix)对10例转移性癌症患者的血浆ccfDNA (OncoScan)和配对肿瘤活检(CytoScan)进行全基因组拷贝数谱分析。采用ASCAT/TuScan和SNP-FASST2对数值型、节段型和局灶性scna进行评估。结果4例ccfDNA的畸变与tDNA的数字畸变(76%)和节段畸变(80%)相似。3例患者由于延迟采样时间、ccfDNA质量和可能的治疗干扰而呈现低相关性。高振幅放大的断点评估具有较高的准确性,相对断点差仅为7%(0.02-37%)。同样,双等位基因的丢失也被可靠地检测到。与肿瘤活检中的SCNAs相比,Array在临床相关基因上检测SCNAs的成功率为100%。对一名患者治疗过程中SCNAs变化的跟踪也表明,可能由治疗引起的非癌细胞凋亡/坏死可以影响ccfDNA组成,并在液体活检分析中引入假阴性结果。结论综合SNP阵列检测液体活检ccfDNA的基因组改变,为患者分层进行靶向治疗提供了可靠的信息来源。临床相关的scna可以在ccfDNA中以高分辨率检测到,因此可以作为肿瘤活检确定治疗靶点的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信