Development of a roof bolter canopy air curtain for respirable dust control.

W R Reed, G J Joy, B Kendall, A Bailey, Y Zheng
{"title":"Development of a roof bolter canopy air curtain for respirable dust control.","authors":"W R Reed,&nbsp;G J Joy,&nbsp;B Kendall,&nbsp;A Bailey,&nbsp;Y Zheng","doi":"10.19150/me.7010","DOIUrl":null,"url":null,"abstract":"<p><p>Testing of the roof bolter canopy air curtain (CAC) designed by the U.S. National Institute for Occupational Safety and Health (NIOSH) has gone through many iterations, demonstrating successful dust control performance under controlled laboratory conditions. J.H. Fletcher & Co., an original equipment manufacturer of mining equipment, further developed the concept by incorporating it into the design of its roof bolting machines. In the present work, laboratory testing was conducted, showing dust control efficiencies ranging from 17.2 to 24.5 percent. Subsequent computational fluid dynamics (CFD) analysis revealed limitations in the design, and a potential improvement was analyzed and recommended. As a result, a new CAC design is being developed, incorporating the results of the testing and CFD analysis.</p>","PeriodicalId":91142,"journal":{"name":"Mining engineering","volume":"69 1","pages":"33-29"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5389459/pdf/nihms843197.pdf","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mining engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19150/me.7010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Testing of the roof bolter canopy air curtain (CAC) designed by the U.S. National Institute for Occupational Safety and Health (NIOSH) has gone through many iterations, demonstrating successful dust control performance under controlled laboratory conditions. J.H. Fletcher & Co., an original equipment manufacturer of mining equipment, further developed the concept by incorporating it into the design of its roof bolting machines. In the present work, laboratory testing was conducted, showing dust control efficiencies ranging from 17.2 to 24.5 percent. Subsequent computational fluid dynamics (CFD) analysis revealed limitations in the design, and a potential improvement was analyzed and recommended. As a result, a new CAC design is being developed, incorporating the results of the testing and CFD analysis.

Abstract Image

Abstract Image

Abstract Image

用于呼吸性粉尘控制的锚杆顶篷气幕的研制。
由美国国家职业安全与健康研究所(NIOSH)设计的锚杆顶篷气幕(CAC)经过多次迭代测试,在受控的实验室条件下展示了成功的粉尘控制性能。J.H. Fletcher & Co.是一家采矿设备的原始设备制造商,通过将其纳入其屋顶锚固机的设计,进一步发展了这一概念。在本工作中,进行了实验室测试,显示粉尘控制效率从17.2%到24.5%不等。随后的计算流体动力学(CFD)分析揭示了设计的局限性,并分析和建议了可能的改进。因此,一种新的CAC设计正在开发中,该设计结合了测试结果和CFD分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信