In vitro evaluation of carrier based obturation technique: a CBCT study.

Annali di stomatologia Pub Date : 2016-07-19 eCollection Date: 2016-01-01 DOI:10.11138/ads/2016.7.1.011
Gianluca Gambarini, Lucila Piasecki, Giovanni Schianchi, Dario Di Nardo, Gabriele Miccoli, Dina Al Sudani, Roberto Di Giorgio, Luca Testarelli
{"title":"In vitro evaluation of carrier based obturation technique: a CBCT study.","authors":"Gianluca Gambarini, Lucila Piasecki, Giovanni Schianchi, Dario Di Nardo, Gabriele Miccoli, Dina Al Sudani, Roberto Di Giorgio, Luca Testarelli","doi":"10.11138/ads/2016.7.1.011","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT.</p><p><strong>Materials and methods: </strong>Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .06 using nickel-titanium instrumentation. The canals in the Group SC were obturated using Soft-Core obturators (Kerr, Romulus, Mi, USA), while Group TH canals (n= 20) were obturated using Thermafil Endodontic Obturators (Tulsa Dental Products, Tulsa, OK, USA), strictly following manufacturers' instructions for use. The obturations were analyzed by means of CBCT to measure the distance from the apical limit of obturation to the apical foramen and the presence of voids inside root canals.</p><p><strong>Results: </strong>There was no significant difference between the two groups in the mean distance of the apical extent of the obturation (t test, p>0.05). Overfilling occurred in only 3 cases (2 in Group TH and 1 in Group SC). The percentages of voids in both groups were very low with no significant difference (Z test, p>0.05).</p><p><strong>Conclusions: </strong>The two tested CBO techniques showed similar positive results in terms of performance, even if, after checking with verifiers, in most cases the size of the selected Soft-Core obturator was one size smaller than Thermafil.</p>","PeriodicalId":78041,"journal":{"name":"Annali di stomatologia","volume":"7 1-2","pages":"11-5"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.11138/ads/2016.7.1.011","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di stomatologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11138/ads/2016.7.1.011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Aim: The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT.

Materials and methods: Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .06 using nickel-titanium instrumentation. The canals in the Group SC were obturated using Soft-Core obturators (Kerr, Romulus, Mi, USA), while Group TH canals (n= 20) were obturated using Thermafil Endodontic Obturators (Tulsa Dental Products, Tulsa, OK, USA), strictly following manufacturers' instructions for use. The obturations were analyzed by means of CBCT to measure the distance from the apical limit of obturation to the apical foramen and the presence of voids inside root canals.

Results: There was no significant difference between the two groups in the mean distance of the apical extent of the obturation (t test, p>0.05). Overfilling occurred in only 3 cases (2 in Group TH and 1 in Group SC). The percentages of voids in both groups were very low with no significant difference (Z test, p>0.05).

Conclusions: The two tested CBO techniques showed similar positive results in terms of performance, even if, after checking with verifiers, in most cases the size of the selected Soft-Core obturator was one size smaller than Thermafil.

Abstract Image

Abstract Image

基于载体的封闭技术的体外评价:一项CBCT研究。
目的:本研究的目的是通过CBCT比较两种不同的载体封闭(CBO)技术在三维根管系统中达到工作长度和填充的能力。材料与方法:对拔出的磨牙进行CBCT扫描,选取30°~ 90°的弯曲根管40根,分为两组(n=20)。使用镍钛器械将所有的根管准备至25锥度。06。SC组使用软核闭孔器(Kerr, Romulus, Mi, USA)进行闭孔,TH组(n= 20)使用Thermafil牙髓闭孔器(Tulsa Dental Products, Tulsa, OK, USA)进行闭孔,严格按照制造商的使用说明进行闭孔。通过CBCT对封闭情况进行分析,测量从根尖封闭极限到根尖孔的距离以及根管内是否存在空隙。结果:两组间封堵顶端距离均值比较,差异无统计学意义(t检验,p < 0.05)。仅3例出现过充(TH组2例,SC组1例)。两组空隙率均极低,差异无统计学意义(Z检验,p < 0.05)。结论:两种测试的CBO技术在性能方面显示出相似的积极结果,即使在与验证者核对后,在大多数情况下所选择的软核闭孔的尺寸比Thermafil小一个尺寸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信