Clinical and Radiological Comparison of Semirigid (WavefleX) and Rigid System for the Lumbar Spine.

Korean Journal of Spine Pub Date : 2016-06-01 Epub Date: 2016-06-30 DOI:10.14245/kjs.2016.13.2.57
Do-Keun Kim, Hyunkeun Lim, Dae Cheol Rim, Chang Hyun Oh
{"title":"Clinical and Radiological Comparison of Semirigid (WavefleX) and Rigid System for the Lumbar Spine.","authors":"Do-Keun Kim,&nbsp;Hyunkeun Lim,&nbsp;Dae Cheol Rim,&nbsp;Chang Hyun Oh","doi":"10.14245/kjs.2016.13.2.57","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Spinal fusion operation is an effective treatment in the spinal pathology, but it could change the physiological distribution of load at the instrumented and adjacent segments. This retrospective study compared the radiological and clinical outcomes of patients undergoing lumbar fusion with semirigid rods versus rigid rods system.</p><p><strong>Methods: </strong>Using transpedicular fixation and posterior lumbar interbody fusion at the level of L4/L5, 20 patients were treated with semirigid rods (WavefleX, SR group), and 20 patients with rigid rods (titanium, RR group). Clinical and radiological outcomes were evaluated, including visual analog score for lower back pain and leg pain, Prolo functional and economic scores, statues of implanted instruments, fusion rate, and complications during 24-month follow-up.</p><p><strong>Results: </strong>Clinical scores were significantly improved until postoperative 24-month follow-up as compared with preoperative scores in both groups (p<0.05), with similar levels of improvement observed at the same time points postoperatively between the 2 groups. Prolo economic scores were significantly improved in SR group compared to RR until 12 months, but this improvement became similar after 18 months. The overall fusion rate was 94.1% until the 24-month follow-up for both groups. No significant complication was observed in both groups.</p><p><strong>Conclusion: </strong>The results of the present study indicate that semirigid rods system with posterior lumbar interbody fusion showed similar clinical and radiological result with rigid rods system until 2 years after instrumentation. The WavefleX rods system, as a semirigid rods with unique characteristics, may be an effective alternative treatment for patients in lumbar fusion.</p>","PeriodicalId":17867,"journal":{"name":"Korean Journal of Spine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.14245/kjs.2016.13.2.57","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Spine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14245/kjs.2016.13.2.57","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/6/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Objective: Spinal fusion operation is an effective treatment in the spinal pathology, but it could change the physiological distribution of load at the instrumented and adjacent segments. This retrospective study compared the radiological and clinical outcomes of patients undergoing lumbar fusion with semirigid rods versus rigid rods system.

Methods: Using transpedicular fixation and posterior lumbar interbody fusion at the level of L4/L5, 20 patients were treated with semirigid rods (WavefleX, SR group), and 20 patients with rigid rods (titanium, RR group). Clinical and radiological outcomes were evaluated, including visual analog score for lower back pain and leg pain, Prolo functional and economic scores, statues of implanted instruments, fusion rate, and complications during 24-month follow-up.

Results: Clinical scores were significantly improved until postoperative 24-month follow-up as compared with preoperative scores in both groups (p<0.05), with similar levels of improvement observed at the same time points postoperatively between the 2 groups. Prolo economic scores were significantly improved in SR group compared to RR until 12 months, but this improvement became similar after 18 months. The overall fusion rate was 94.1% until the 24-month follow-up for both groups. No significant complication was observed in both groups.

Conclusion: The results of the present study indicate that semirigid rods system with posterior lumbar interbody fusion showed similar clinical and radiological result with rigid rods system until 2 years after instrumentation. The WavefleX rods system, as a semirigid rods with unique characteristics, may be an effective alternative treatment for patients in lumbar fusion.

Abstract Image

Abstract Image

Abstract Image

腰椎半刚性(WavefleX)和刚性系统的临床和影像学比较。
目的:脊柱融合手术是治疗脊柱病变的有效方法,但会改变固定节段及相邻节段的负荷生理分布。本回顾性研究比较了半刚性椎棒与刚性椎棒系统腰椎融合患者的放射学和临床结果。方法:采用经椎弓根固定和后路腰4/L5椎体间融合术治疗20例半刚性棒(WavefleX, SR组)和20例刚性棒(钛合金,RR组)。评估临床和放射学结果,包括腰痛和腿痛的视觉模拟评分、Prolo功能和经济评分、植入器械的状态、融合率和24个月随访期间的并发症。结果:两组患者在术后24个月随访前的临床评分均较术前有显著提高(结论:本研究结果表明,半刚性棒系统合并后路腰椎椎体间融合在内固定2年后的临床和影像学结果与刚性棒系统相似。WavefleX棒系统作为一种具有独特特点的半刚性棒,可能是腰椎融合术患者的有效替代治疗方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信