{"title":"Comparative analysis of the retention of maxillary denture base with and without border molding using zinc oxide eugenol impression paste.","authors":"Simrat Kaur, Kusum Datta, S K Gupta, Neelam Suman","doi":"10.4103/0975-962X.179380","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims and objectives: </strong>The purpose of the study was to determine the effect of border molding on the retention of the maxillary denture base.</p><p><strong>Materials and methods: </strong>Two special trays, one with full extensions to the periphery and one 2 mm short from the borders were made on the cast obtained from the preliminary impression. Border molding was done on the tray which was short from borders. On both trays, the final impression was made with zinc oxide eugenol impression paste. Heat cure denture bases were fabricated on the prepared casts and retention was measured using specially designed instrument.</p><p><strong>Observations and results: </strong>Mean force with border molding (2765.0 g) was larger than mean force without border molding (1805.0 g) at P < 0.01 level. In terms of percentage, too, the mean improvement (59.4%) in force of dislodgement was statistically highly significant (i.e. P < 0.01).</p><p><strong>Clinical significance: </strong>The results of the present study suggest that the dentures made with border molding will provide better retentive force than the dentures made without border molding.</p>","PeriodicalId":90526,"journal":{"name":"Indian journal of dentistry","volume":"7 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/90/1a/IJDENT-7-1.PMC4836091.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian journal of dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/0975-962X.179380","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aims and objectives: The purpose of the study was to determine the effect of border molding on the retention of the maxillary denture base.
Materials and methods: Two special trays, one with full extensions to the periphery and one 2 mm short from the borders were made on the cast obtained from the preliminary impression. Border molding was done on the tray which was short from borders. On both trays, the final impression was made with zinc oxide eugenol impression paste. Heat cure denture bases were fabricated on the prepared casts and retention was measured using specially designed instrument.
Observations and results: Mean force with border molding (2765.0 g) was larger than mean force without border molding (1805.0 g) at P < 0.01 level. In terms of percentage, too, the mean improvement (59.4%) in force of dislodgement was statistically highly significant (i.e. P < 0.01).
Clinical significance: The results of the present study suggest that the dentures made with border molding will provide better retentive force than the dentures made without border molding.
目的和目标:研究的目的是确定边缘成型对上颌义齿基托固位的影响:在根据初步印模制作的模型上制作了两个特殊的托盘,一个向周边完全延伸,另一个距边界短2毫米。在距边界较短的托盘上进行边界成型。在这两个托盘上,使用氧化锌丁香酚印模膏制作最终印模。在制备好的模型上制作热固化义齿基托,并使用专门设计的仪器测量固位力:在 P < 0.01 的水平上,使用边界模塑的平均力(2765.0 克)大于不使用边界模塑的平均力(1805.0 克)。就百分比而言,脱落力的平均改善率(59.4%)在统计学上也非常显著(即 P < 0.01):临床意义:本研究结果表明,与未进行边界模塑的假牙相比,进行边界模塑的假牙能提供更好的固位力。