{"title":"Key points of reducing neurologic complications in frozen elephant trunk technique.","authors":"Murat Kadan, Gokhan Erol, Kubilay Karabacak, Mevlüt Kobuk","doi":"10.5935/1678-9741.20150056","DOIUrl":null,"url":null,"abstract":"We have read the interesting article entitled “Surgical treatment of complex aneurysms and thoracic aortic dissections with the Frozen Elephant Trunk technique” carefully[1]. The authors report their initial experience with this technique in 21 patients. First of all we appreciated the authors for this nice study. We would like to add some critics about this study. There were some neurologic complications such as stroke (in one patient) and paraplegia (in two patients) in the study. Did the authors make any assessment about neurologic complications and their protection strategies? This is a very important point that should be detailed in paper. The exact mechanism of spinal cord injury in frozen elephant trunk interventions is not fully understood. Stent graft length, thromboembolism, and spinal cord ischemia time during total circulatory arrest are considered responsible factors[2]. Cerebrospinal fluid drainage is recommended for spinal cord protection strategy in current guideline (Class I, level of evidence B)[3]. Proximal aortic pressure maintenance and distal aortic perfusion are some of the other recommendations (Class IIa, level of evidence B). From this point, did the authors use any of suggested protection method? On the other hand, neurologic complications can also be associated with distal length of endovascular prosthesis. In literature, 130 mm stent length is recommended for preventing paraplegia[2]. What was the distal length of prosthesis in these patients? Did authors make any assessment about distal position of stent in patients with neurologic complications? The authors performed surgery in conventional operating room, without the use of scopes or guidewire. How can authors identify the true lumen? Wasn’t it a risk? Can mentioned neurologic complications as well as renal failure be associated with possible selection of incorrect lumen? Why didn’t authors use guidewire? Has the dissection also included both femoral arteries? Hybrid operating room doesn’t exist in many centers, however, guidewire may be used to identify true lumen. In our center, we also don’t have hybrid operating room, but we routinely use guidewire from intact femoral artery through descending thoracic aorta in retrograde way. Therefore we are able to see the true lumen directly. In conclusion, we consider that, this single stage technique is so useful especially in complex aortic pathologies. Learning curve is a reality of these novel strategies of course, but morbidity rates can be decreased with appropriate surgical strategies and known guideline recommendations.","PeriodicalId":87739,"journal":{"name":"Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular","volume":"30 4","pages":"505-6"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4614938/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5935/1678-9741.20150056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We have read the interesting article entitled “Surgical treatment of complex aneurysms and thoracic aortic dissections with the Frozen Elephant Trunk technique” carefully[1]. The authors report their initial experience with this technique in 21 patients. First of all we appreciated the authors for this nice study. We would like to add some critics about this study. There were some neurologic complications such as stroke (in one patient) and paraplegia (in two patients) in the study. Did the authors make any assessment about neurologic complications and their protection strategies? This is a very important point that should be detailed in paper. The exact mechanism of spinal cord injury in frozen elephant trunk interventions is not fully understood. Stent graft length, thromboembolism, and spinal cord ischemia time during total circulatory arrest are considered responsible factors[2]. Cerebrospinal fluid drainage is recommended for spinal cord protection strategy in current guideline (Class I, level of evidence B)[3]. Proximal aortic pressure maintenance and distal aortic perfusion are some of the other recommendations (Class IIa, level of evidence B). From this point, did the authors use any of suggested protection method? On the other hand, neurologic complications can also be associated with distal length of endovascular prosthesis. In literature, 130 mm stent length is recommended for preventing paraplegia[2]. What was the distal length of prosthesis in these patients? Did authors make any assessment about distal position of stent in patients with neurologic complications? The authors performed surgery in conventional operating room, without the use of scopes or guidewire. How can authors identify the true lumen? Wasn’t it a risk? Can mentioned neurologic complications as well as renal failure be associated with possible selection of incorrect lumen? Why didn’t authors use guidewire? Has the dissection also included both femoral arteries? Hybrid operating room doesn’t exist in many centers, however, guidewire may be used to identify true lumen. In our center, we also don’t have hybrid operating room, but we routinely use guidewire from intact femoral artery through descending thoracic aorta in retrograde way. Therefore we are able to see the true lumen directly. In conclusion, we consider that, this single stage technique is so useful especially in complex aortic pathologies. Learning curve is a reality of these novel strategies of course, but morbidity rates can be decreased with appropriate surgical strategies and known guideline recommendations.
减少冷冻象鼻术神经并发症的要点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书