{"title":"Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty.","authors":"Pier Francesco Indelli,&nbsp;Angelo Graceffa,&nbsp;Andrea Baldini,&nbsp;Brielle Payne,&nbsp;Gennaro Pipino,&nbsp;Massimiliano Marcucci","doi":"10.1155/2015/189294","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-stabilized (PS) symmetric tibial baseplate while Group 2 included 24 females and 16 males receiving a PS anatomical tibial component. Identical surgical technique, including the use of the surgical transepicondylar femoral axis (sTEA) and the anterior tibial cortex (\"Curve-on-Curve\") as rotational alignment landmarks, was used. All patients underwent CT evaluation performed with the knee in full extension. Three observers independently measured the rotational alignment of the tibial component in relation to the sTEA. The rotational alignment of the symmetric baseplate showed an average external rotation of 1.3° (minimum 5°, maximum -1°): 91% of the knees showed 0 ± 3° with respect to the surgical sTEA, being internally rotated in 20%. The rotational alignment of the anatomical baseplate showed an average external rotation of 4.1° (minimum 0.4°, maximum 8.9°): only 47.5% of the knees showed 0 ± 3°, being externally rotated in 100%. The difference between the two groups was statistically significant. This study confirms the reliability of the \"Curve-on-Curve\" technique as an adequate rotational alignment anatomical landmark in TKA: the use of an asymmetric tibial baseplate might lead to external rotation of the tibial component when this technique is intraoperatively chosen. </p>","PeriodicalId":89323,"journal":{"name":"Arthritis","volume":"2015 ","pages":"189294"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2015/189294","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthritis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2015/189294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/9/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-stabilized (PS) symmetric tibial baseplate while Group 2 included 24 females and 16 males receiving a PS anatomical tibial component. Identical surgical technique, including the use of the surgical transepicondylar femoral axis (sTEA) and the anterior tibial cortex ("Curve-on-Curve") as rotational alignment landmarks, was used. All patients underwent CT evaluation performed with the knee in full extension. Three observers independently measured the rotational alignment of the tibial component in relation to the sTEA. The rotational alignment of the symmetric baseplate showed an average external rotation of 1.3° (minimum 5°, maximum -1°): 91% of the knees showed 0 ± 3° with respect to the surgical sTEA, being internally rotated in 20%. The rotational alignment of the anatomical baseplate showed an average external rotation of 4.1° (minimum 0.4°, maximum 8.9°): only 47.5% of the knees showed 0 ± 3°, being externally rotated in 100%. The difference between the two groups was statistically significant. This study confirms the reliability of the "Curve-on-Curve" technique as an adequate rotational alignment anatomical landmark in TKA: the use of an asymmetric tibial baseplate might lead to external rotation of the tibial component when this technique is intraoperatively chosen.

Abstract Image

Abstract Image

Abstract Image

初次全膝关节置换术中胫骨基板设计与旋转对齐标志的关系。
本研究评估了在TKA中使用胫骨前皮质作为胫骨基板的主要旋转标记时,现代胫骨基板设计的影响。80例TKA患者随机分为两组。组1包括25名女性和15名男性接受后稳定(PS)对称胫骨基板,组2包括24名女性和16名男性接受PS解剖胫骨组件。采用相同的手术技术,包括使用手术经耻骨髁股骨轴(sTEA)和胫骨前皮质(“曲线对曲线”)作为旋转对齐标志。所有患者均在膝关节完全伸展时进行了CT评估。三名观察员独立测量了与sTEA相关的胫骨组件的旋转对齐。对称基板的旋转对齐显示平均外旋1.3°(最小5°,最大-1°):91%的膝关节相对于手术sTEA为0±3°,20%为内旋。解剖底板的旋转对齐显示平均外旋4.1°(最小0.4°,最大8.9°):只有47.5%的膝关节为0±3°,外旋率为100%。两组间差异有统计学意义。本研究证实了“曲线对曲线”技术作为TKA中适当的旋转对准解剖标志的可靠性:术中选择不对称胫骨基板可能导致胫骨构件外旋。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书