One-Per-Mil Tumescent Infiltration Technique for Vascular Malformation Surgery in Hand and Upper Extremity.

Theddeus O H Prasetyono, Jesslyn Gustin
{"title":"One-Per-Mil Tumescent Infiltration Technique for Vascular Malformation Surgery in Hand and Upper Extremity.","authors":"Theddeus O H Prasetyono,&nbsp;Jesslyn Gustin","doi":"10.1142/S0218810415500380","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To present the efficacy of 1:1,000,000 tumescent solution for resection of vascular malformation in hand and upper extremity without tourniquet application.</p><p><strong>Methods: </strong>Four patients with five slow flow vascular malformations were retrospectively reviewed. Prior to incision, 1:1,000,000 tumescent solution was infiltrated subcutaneously surrounding the lesion until the skin turned pale. Amount of tumescent solution injected, the length of surgery, the clarity of the operative field, and the complications were recorded. Clarity of operative field was categorized as totally bloodless, minimum bleeding, acceptable bleeding, and bloody. In the surgeries under local anesthesia, we also recorded self-reported intra-operative pain using VAS score, onset of pain, and conversion of anesthesia.</p><p><strong>Results: </strong>The injected amount of the tumescent solution ranged from 4.5 to 200 mL, with the length of surgery ranged from 60 to 150 minutes. One out of 5 cases was totally bloodless, 3 cases were minimum bleeding and 1 case was acceptable bleeding. Minor skin necrosis was recorded in 1 patient. Neither intra-operative pain nor conversion from local to general anesthesia was reported.</p><p><strong>Conclusions: </strong>1:1,000,000 tumescent solution is effective for resection of slow flow vascular malformation in hand and upper extremity without tourniquet application.</p>","PeriodicalId":80280,"journal":{"name":"Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand","volume":"20 3","pages":"447-52"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1142/S0218810415500380","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S0218810415500380","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Background: To present the efficacy of 1:1,000,000 tumescent solution for resection of vascular malformation in hand and upper extremity without tourniquet application.

Methods: Four patients with five slow flow vascular malformations were retrospectively reviewed. Prior to incision, 1:1,000,000 tumescent solution was infiltrated subcutaneously surrounding the lesion until the skin turned pale. Amount of tumescent solution injected, the length of surgery, the clarity of the operative field, and the complications were recorded. Clarity of operative field was categorized as totally bloodless, minimum bleeding, acceptable bleeding, and bloody. In the surgeries under local anesthesia, we also recorded self-reported intra-operative pain using VAS score, onset of pain, and conversion of anesthesia.

Results: The injected amount of the tumescent solution ranged from 4.5 to 200 mL, with the length of surgery ranged from 60 to 150 minutes. One out of 5 cases was totally bloodless, 3 cases were minimum bleeding and 1 case was acceptable bleeding. Minor skin necrosis was recorded in 1 patient. Neither intra-operative pain nor conversion from local to general anesthesia was reported.

Conclusions: 1:1,000,000 tumescent solution is effective for resection of slow flow vascular malformation in hand and upper extremity without tourniquet application.

1 / ml肿胀浸润技术在手部及上肢血管畸形手术中的应用。
背景:观察1:10 0万肿胀液在不带止血带的情况下切除手部及上肢血管畸形的疗效。方法:回顾性分析5例慢血流血管畸形患者的临床资料。切口前,在病灶周围皮下浸润1:10 00000肿胀溶液,直至皮肤变白。记录肿胀液注射量、手术时间、手术视野清晰度及并发症发生情况。手术野清晰度分为完全无血、少量出血、可接受出血和有血。在局部麻醉下的手术中,我们也用VAS评分记录术中自我报告的疼痛,疼痛的发生和麻醉的转换。结果:肿胀液的注射量为4.5 ~ 200 mL,手术时间为60 ~ 150 min。1例完全无血,3例轻度出血,1例可接受出血。1例出现轻微皮肤坏死。术中疼痛和从局麻到全麻的转换均无报道。结论:1:10 0万肿胀液在不使用止血带的情况下可有效切除手部及上肢慢流血管畸形。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书