{"title":"Performance of a pedometer to measure physical activity in a U.S. cohort with chronic obstructive pulmonary disease.","authors":"Valery A Danilack,&nbsp;Osarenoma Okunbor,&nbsp;Caroline R Richardson,&nbsp;Merilee Teylan,&nbsp;Marilyn L Moy","doi":"10.1682/JRRD.2014.11.0282","DOIUrl":null,"url":null,"abstract":"<p><p>Objective assessment of physical activity (PA) in chronic obstructive pulmonary disease (COPD) is important. We examined the performance of the Omron HJ-720ITC pedometer. A sample of 176 persons with stable COPD wore the Omron and the StepWatch Activity Monitor (SAM) in the clinic and the community. A 4 s step filter in the Omron screens out erroneous intermittent steps; it captures continuous walking that lasts >4 s. The SAM captures all intermittent and continuous steps walked. Omron-steps were compared with manually counted steps in the clinic and with SAM-steps in the community. We calculated the intraclass correlation coefficient for the first 2 d, the first 3 d, etc., up to 14 d. The Omron registered >/= 90% of the manually counted steps from the in-clinic walk in 155 of 176 subjects (88%). In the community, 47 +/- 16% of SAM-steps were continuous ones that were captured by the Omron. For the Omron and the SAM, at least 7 d of monitoring should be used to capture decreases in PA on weekend days and obtain optimum reliability for all Global Initiative for Chronic Obstructive Lung Disease stages. The Omron accurately and reliably measures continuous walking in COPD. The Omron may be ideal for use in PA interventions that promote continuous walking as exercise. </p>","PeriodicalId":50065,"journal":{"name":"Journal of Rehabilitation Research and Development","volume":"52 3","pages":"333-42"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1682/JRRD.2014.11.0282","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation Research and Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1682/JRRD.2014.11.0282","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 13

Abstract

Objective assessment of physical activity (PA) in chronic obstructive pulmonary disease (COPD) is important. We examined the performance of the Omron HJ-720ITC pedometer. A sample of 176 persons with stable COPD wore the Omron and the StepWatch Activity Monitor (SAM) in the clinic and the community. A 4 s step filter in the Omron screens out erroneous intermittent steps; it captures continuous walking that lasts >4 s. The SAM captures all intermittent and continuous steps walked. Omron-steps were compared with manually counted steps in the clinic and with SAM-steps in the community. We calculated the intraclass correlation coefficient for the first 2 d, the first 3 d, etc., up to 14 d. The Omron registered >/= 90% of the manually counted steps from the in-clinic walk in 155 of 176 subjects (88%). In the community, 47 +/- 16% of SAM-steps were continuous ones that were captured by the Omron. For the Omron and the SAM, at least 7 d of monitoring should be used to capture decreases in PA on weekend days and obtain optimum reliability for all Global Initiative for Chronic Obstructive Lung Disease stages. The Omron accurately and reliably measures continuous walking in COPD. The Omron may be ideal for use in PA interventions that promote continuous walking as exercise.

计步器在美国慢性阻塞性肺疾病队列中测量身体活动的性能
客观评估慢性阻塞性肺疾病(COPD)患者的身体活动(PA)是很重要的。我们测试了欧姆龙HJ-720ITC计步器的性能。176名稳定期COPD患者在诊所和社区佩戴欧姆龙和StepWatch活动监测仪(SAM)。欧姆龙的4秒级过滤器可以过滤掉错误的间歇步骤;它捕捉持续超过4秒的连续行走。SAM捕获所有间歇和连续的步数。将欧姆龙步数与诊所的人工计算步数和社区的sam步数进行比较。我们计算了前2天、前3天等直至14天的类内相关系数。在176名受试者中,155名受试者(88%)中,欧姆龙记录了>/= 90%的人工计算步数。在社区中,有47 +/- 16%的sam步骤是由欧姆龙捕获的连续步骤。对于欧姆龙和SAM,至少7天的监测应用于捕获周末PA的减少,并获得慢性阻塞性肺疾病全球倡议所有阶段的最佳可靠性。欧姆龙准确可靠地测量慢性阻塞性肺病患者的持续步行。欧姆龙可能是理想的用于PA干预,促进持续步行作为锻炼。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.64
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信