Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor.

Q Medicine
Pietro Picerno, Valerio Viero, Marco Donati, Tamara Triossi, Virginia Tancredi, Giovanni Melchiorri
{"title":"Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor.","authors":"Pietro Picerno,&nbsp;Valerio Viero,&nbsp;Marco Donati,&nbsp;Tamara Triossi,&nbsp;Virginia Tancredi,&nbsp;Giovanni Melchiorri","doi":"10.1682/JRRD.2014.06.0146","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the present article was to assess the reliability of strength curves as determined from tridimensional linear accelerations and angular velocities measured by a single inertial measurement unit (IMU) fixed on the upper arm during a shoulder abduction movement performed holding a 1 kg dumbbell in the hand. Within-subject repeatability of the task was assessed on 45 subjects performing four trials consisting of one maximal shoulder abduction-adduction movement. Intraclass correlation coefficient (ICC) was computed on the average movement angular velocity (VEL) and range of movement (ROM) across the four trials. Within-subject repeatability of torque curves was assessed in terms of waveform similarities by computing the coefficient of multiple determination (CMD). Accuracy of the estimated ROM was assessed using an isokinetic dynamometer. High ICC values of ROM (0.955) and VEL (0.970) indicated a high within-subject repeatability of the task. A high waveform similarity of torque curves was also found between trials (CMD = 0.867). Accuracy with respect to isokinetic dynamometer in estimating ROM was always <1 degree (p = 0.37). This study showed the effectiveness of using a single wearable IMU for the assessment of strength curve during isoinertial movements in a way that complies with the needs of clinicians in an ambulatory setting. </p>","PeriodicalId":50065,"journal":{"name":"Journal of Rehabilitation Research and Development","volume":"52 2","pages":"171-80"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1682/JRRD.2014.06.0146","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation Research and Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1682/JRRD.2014.06.0146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 23

Abstract

The aim of the present article was to assess the reliability of strength curves as determined from tridimensional linear accelerations and angular velocities measured by a single inertial measurement unit (IMU) fixed on the upper arm during a shoulder abduction movement performed holding a 1 kg dumbbell in the hand. Within-subject repeatability of the task was assessed on 45 subjects performing four trials consisting of one maximal shoulder abduction-adduction movement. Intraclass correlation coefficient (ICC) was computed on the average movement angular velocity (VEL) and range of movement (ROM) across the four trials. Within-subject repeatability of torque curves was assessed in terms of waveform similarities by computing the coefficient of multiple determination (CMD). Accuracy of the estimated ROM was assessed using an isokinetic dynamometer. High ICC values of ROM (0.955) and VEL (0.970) indicated a high within-subject repeatability of the task. A high waveform similarity of torque curves was also found between trials (CMD = 0.867). Accuracy with respect to isokinetic dynamometer in estimating ROM was always <1 degree (p = 0.37). This study showed the effectiveness of using a single wearable IMU for the assessment of strength curve during isoinertial movements in a way that complies with the needs of clinicians in an ambulatory setting.

基于单穿戴惯性传感器的肩部外展强度曲线动态评估。
本文的目的是评估强度曲线的可靠性,该曲线由固定在上臂上的单个惯性测量单元(IMU)在肩部外展运动中测量的三维线性加速度和角速度确定。对45名受试者进行了四次试验,包括一次最大的肩部外展-内收运动,评估了该任务的受试者内重复性。通过四个试验的平均运动角速度(VEL)和运动范围(ROM)计算类内相关系数(ICC)。通过计算多重确定系数(CMD),根据波形相似度评估扭矩曲线的受试者内重复性。使用等速测功机评估预估ROM的准确性。高ICC值ROM(0.955)和VEL(0.970)表明任务的高受试者内重复性。试验之间的扭矩曲线波形相似度较高(CMD = 0.867)。等速测功机在估算ROM时,精度一直存在问题
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.64
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信