Improved Detection of Kidney Stones Using an Optimized Doppler Imaging Sequence.

Bryan Cunitz, Barbrina Dunmire, Marla Paun, Oleg Sapozhnikov, John Kucewicz, Ryan Hsi, Franklin Lee, Matthew Sorensen, Jonathan Harper, Michael Bailey
{"title":"Improved Detection of Kidney Stones Using an Optimized Doppler Imaging Sequence.","authors":"Bryan Cunitz,&nbsp;Barbrina Dunmire,&nbsp;Marla Paun,&nbsp;Oleg Sapozhnikov,&nbsp;John Kucewicz,&nbsp;Ryan Hsi,&nbsp;Franklin Lee,&nbsp;Matthew Sorensen,&nbsp;Jonathan Harper,&nbsp;Michael Bailey","doi":"10.1109/ULTSYM.2014.0112","DOIUrl":null,"url":null,"abstract":"<p><p>Kidney stones have been shown to exhibit a \"twinkling artifact\" (TA) under Color-Doppler ultrasound. Although this technique has better specificity than conventional Bmode imaging, it has lower sensitivity. To improve the overall performance of using TA as a diagnostic tool, Doppler output parameters were optimized <i>in-vitro</i>. The collected data supports a previous hypothesis that TA is caused by random oscillations of micron sized bubbles trapped in the cracks and crevices of kidney stones. A set of optimized parameters were implemented such that that the MI & TI remained within the FDA approved limits. Several clinical kidney scans were performed with the optimized settings and were able to detect stones with improved SNR relative to the default settings.</p>","PeriodicalId":73288,"journal":{"name":"IEEE International Ultrasonics Symposium : [proceedings]. IEEE International Ultrasonics Symposium","volume":"2014 ","pages":"452-455"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/ULTSYM.2014.0112","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Ultrasonics Symposium : [proceedings]. IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2014.0112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

Kidney stones have been shown to exhibit a "twinkling artifact" (TA) under Color-Doppler ultrasound. Although this technique has better specificity than conventional Bmode imaging, it has lower sensitivity. To improve the overall performance of using TA as a diagnostic tool, Doppler output parameters were optimized in-vitro. The collected data supports a previous hypothesis that TA is caused by random oscillations of micron sized bubbles trapped in the cracks and crevices of kidney stones. A set of optimized parameters were implemented such that that the MI & TI remained within the FDA approved limits. Several clinical kidney scans were performed with the optimized settings and were able to detect stones with improved SNR relative to the default settings.

Abstract Image

利用优化多普勒成像序列改进肾结石的检测。
肾结石在彩色多普勒超声下显示出“闪烁伪影”(TA)。虽然该技术比传统的b模成像具有更好的特异性,但其灵敏度较低。为了提高TA作为诊断工具的整体性能,体外优化了多普勒输出参数。收集到的数据支持了先前的假设,即TA是由被困在肾结石裂缝和裂隙中的微米级气泡的随机振荡引起的。实施了一组优化参数,使MI和TI保持在FDA批准的范围内。在优化的设置下进行了几次临床肾脏扫描,并且能够以相对于默认设置的改进的信噪比检测结石。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信