Accuracy of pulse oximetry screening for detecting critical congenital heart disease in the newborns in rural hospital of Central India.

Images in paediatric cardiology Pub Date : 2013-10-01
A M Taksande, B Lakhkar, A Gadekar, K Suwarnakar, T Japzape
{"title":"Accuracy of pulse oximetry screening for detecting critical congenital heart disease in the newborns in rural hospital of Central India.","authors":"A M Taksande,&nbsp;B Lakhkar,&nbsp;A Gadekar,&nbsp;K Suwarnakar,&nbsp;T Japzape","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Congenital cardiovascular malformations are the most common category of birth defects and responsible for mortality in the first twelve months of life. Critical congenital heart disease (CCHD) will be present in approximately one quarter of these children, which requires catheter or surgery intervention in the first year of life.</p><p><strong>Aim: </strong>To determine the accuracy of pulse oximetry for detecting clinically unrecognized CCHD in the newborns.</p><p><strong>Methods: </strong>Pulse oximetry was performed on clinically normal newborns within first 4 hours of life. If screening oxygen saturation (SpO2) was below 90%, echocardiography was then performed.</p><p><strong>Inclusion criteria: </strong>All newborns who were admitted in postnatal ward & NICU.</p><p><strong>Exclusion criteria: </strong>Out born babies and babies with a prenatal diagnosis of duct dependent circulation.</p><p><strong>Results: </strong>Pulse-oximetric screening was performed on 2110 clinically normal newborns. Low SpO2 (<90%) was found in eight babies seven of them had CCHD, including three neonates with TGA, two with tricuspid atresia, one with tetralogy of fallot and one with transposition of great vessels. A pulse oximetry cut-off value of below 90% for detecting CCHD showed 100% sensitivity, 99.95% specificity, 87.50% positive predictive value, 100% negative predictive value.</p><p><strong>Conclusions: </strong>Pulse oximetry is safe, feasible and noninvasive, can be used as screening tool for detecting CCHD in clinically normal newborn. If SpO2 is below 90% in clinically normal newborns within 4 hours of birth, urgent echocardiography is suggested to rule out CCHD.</p>","PeriodicalId":89564,"journal":{"name":"Images in paediatric cardiology","volume":"15 4","pages":"5-10"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4521327/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Images in paediatric cardiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Congenital cardiovascular malformations are the most common category of birth defects and responsible for mortality in the first twelve months of life. Critical congenital heart disease (CCHD) will be present in approximately one quarter of these children, which requires catheter or surgery intervention in the first year of life.

Aim: To determine the accuracy of pulse oximetry for detecting clinically unrecognized CCHD in the newborns.

Methods: Pulse oximetry was performed on clinically normal newborns within first 4 hours of life. If screening oxygen saturation (SpO2) was below 90%, echocardiography was then performed.

Inclusion criteria: All newborns who were admitted in postnatal ward & NICU.

Exclusion criteria: Out born babies and babies with a prenatal diagnosis of duct dependent circulation.

Results: Pulse-oximetric screening was performed on 2110 clinically normal newborns. Low SpO2 (<90%) was found in eight babies seven of them had CCHD, including three neonates with TGA, two with tricuspid atresia, one with tetralogy of fallot and one with transposition of great vessels. A pulse oximetry cut-off value of below 90% for detecting CCHD showed 100% sensitivity, 99.95% specificity, 87.50% positive predictive value, 100% negative predictive value.

Conclusions: Pulse oximetry is safe, feasible and noninvasive, can be used as screening tool for detecting CCHD in clinically normal newborn. If SpO2 is below 90% in clinically normal newborns within 4 hours of birth, urgent echocardiography is suggested to rule out CCHD.

Abstract Image

脉搏血氧仪筛查在印度中部农村医院检测新生儿重症先天性心脏病的准确性。
背景:先天性心血管畸形是出生缺陷中最常见的一类,是导致出生后12个月死亡率的主要原因。危重先天性心脏病(CCHD)将出现在大约四分之一的这些儿童中,这需要在生命的第一年进行导管或手术干预。目的:探讨脉搏血氧仪检测新生儿临床未被识别的冠心病的准确性。方法:对临床正常新生儿在出生后4小时内进行脉搏血氧测定。若筛查血氧饱和度(SpO2)低于90%,则行超声心动图检查。纳入标准:所有在产后病房和新生儿重症监护病房入住的新生儿。排除标准:出生的婴儿和产前诊断为导管依赖循环的婴儿。结果:对2110例临床正常新生儿进行了脉搏血氧筛查。结论:脉搏血氧仪安全、可行、无创,可作为临床正常新生儿CCHD的筛查工具。临床正常新生儿出生4小时内SpO2低于90%,建议紧急超声心动图排除CCHD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书