Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review.

Q Medicine
Stephanie L Carey, Derek J Lura, M Jason Highsmith
{"title":"Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review.","authors":"Stephanie L Carey, Derek J Lura, M Jason Highsmith","doi":"10.1682/JRRD.2014.08.0192","DOIUrl":null,"url":null,"abstract":"<p><p>The choice of a myoelectric or body-powered upper-limb prosthesis can be determined using factors including control, function, feedback, cosmesis, and rejection. Although body-powered and myoelectric control strategies offer unique functions, many prosthesis users must choose one. A systematic review was conducted to determine differences between myoelectric and body-powered prostheses to inform evidence-based clinical practice regarding prescription of these devices and training of users. A search of 9 databases identified 462 unique publications. Ultimately, 31 of them were included and 11 empirical evidence statements were developed. Conflicting evidence has been found in terms of the relative functional performance of body-powered and myoelectric prostheses. Body-powered prostheses have been shown to have advantages in durability, training time, frequency of adjustment, maintenance, and feedback; however, they could still benefit from improvements of control. Myoelectric prostheses have been shown to improve cosmesis and phantom-limb pain and are more accepted for light=intensity work. Currently, evidence is insufficient to conclude that either system provides a significant general advantage. Prosthetic selection should be based on a patient's individual needs and include personal preferences, prosthetic experience, and functional needs. This work demonstrates that there is a lack of empirical evidence regarding functional differences in upper-limb prostheses. </p>","PeriodicalId":50065,"journal":{"name":"Journal of Rehabilitation Research and Development","volume":"52 3","pages":"247-62"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation Research and Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1682/JRRD.2014.08.0192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The choice of a myoelectric or body-powered upper-limb prosthesis can be determined using factors including control, function, feedback, cosmesis, and rejection. Although body-powered and myoelectric control strategies offer unique functions, many prosthesis users must choose one. A systematic review was conducted to determine differences between myoelectric and body-powered prostheses to inform evidence-based clinical practice regarding prescription of these devices and training of users. A search of 9 databases identified 462 unique publications. Ultimately, 31 of them were included and 11 empirical evidence statements were developed. Conflicting evidence has been found in terms of the relative functional performance of body-powered and myoelectric prostheses. Body-powered prostheses have been shown to have advantages in durability, training time, frequency of adjustment, maintenance, and feedback; however, they could still benefit from improvements of control. Myoelectric prostheses have been shown to improve cosmesis and phantom-limb pain and are more accepted for light=intensity work. Currently, evidence is insufficient to conclude that either system provides a significant general advantage. Prosthetic selection should be based on a patient's individual needs and include personal preferences, prosthetic experience, and functional needs. This work demonstrates that there is a lack of empirical evidence regarding functional differences in upper-limb prostheses.

肌电式和身体动力式上肢假体的差异:系统文献综述。
选择肌电式或身体动力式上肢假肢可以根据控制、功能、反馈、外观和排斥等因素来决定。虽然身体动力和肌电控制策略提供了独特的功能,但许多义肢使用者必须选择一种。进行了一项系统评价,以确定肌电假体和身体动力假体之间的差异,为这些装置的处方和使用者培训提供循证临床实践。对9个数据库的搜索确定了462种独特的出版物。最终,共纳入31个研究对象,形成了11个实证陈述。在身体动力假体和肌电假体的相对功能表现方面,发现了相互矛盾的证据。身体动力假肢在耐用性、训练时间、调整频率、维护和反馈方面具有优势;然而,他们仍然可以从控制的改进中受益。肌电假体已被证明可以改善美容和幻肢疼痛,并且更被接受用于轻强度工作。目前,还没有足够的证据表明这两种制度都具有显著的普遍优势。义肢的选择应基于患者的个人需求,包括个人偏好、义肢经验和功能需求。这项工作表明,缺乏关于上肢假肢功能差异的经验证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.64
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信