Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures.

Masaaki Akahane, Naoki Yoshioka, Shigeru Kiryu
{"title":"Radiation Protection of the Eye Lens in Fluoroscopy-guided Interventional Procedures.","authors":"Masaaki Akahane, Naoki Yoshioka, Shigeru Kiryu","doi":"10.22575/interventionalradiology.2022-0006","DOIUrl":null,"url":null,"abstract":"<p><p>The medical staff involved in fluoroscopy-guided procedures are at potential risks of radiation-induced cataract. Therefore, proper monitoring of the lens doses is critical, and radiation protection should be provided to the maximum extent that is reasonably achievable. The collar dosimeter is necessary to avoid underestimation of the lens dose, and the third dosimeter behind the protective eyewear would be helpful for those who are likely to exceed the dose limit. The reduction of the patient doses will correspondingly reduce the staff doses. Proper placement of the ceiling-mounted shields and minimization of the face-to-glass gap are the keys to effective shielding. The optimization of procedures and devices that help maintain a distance from the irradiated area and to prevent the looking-up posture will substantially reduce the lens dose.</p>","PeriodicalId":73503,"journal":{"name":"Interventional radiology (Higashimatsuyama-shi (Japan)","volume":"7 2","pages":"44-48"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/4b/9e/2432-0935-7-2-0044.PMC9527101.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional radiology (Higashimatsuyama-shi (Japan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22575/interventionalradiology.2022-0006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The medical staff involved in fluoroscopy-guided procedures are at potential risks of radiation-induced cataract. Therefore, proper monitoring of the lens doses is critical, and radiation protection should be provided to the maximum extent that is reasonably achievable. The collar dosimeter is necessary to avoid underestimation of the lens dose, and the third dosimeter behind the protective eyewear would be helpful for those who are likely to exceed the dose limit. The reduction of the patient doses will correspondingly reduce the staff doses. Proper placement of the ceiling-mounted shields and minimization of the face-to-glass gap are the keys to effective shielding. The optimization of procedures and devices that help maintain a distance from the irradiated area and to prevent the looking-up posture will substantially reduce the lens dose.

荧光镜引导的介入手术中眼球晶状体的辐射防护。
参与荧光透视引导手术的医务人员面临辐射诱发白内障的潜在风险。因此,正确监测镜片剂量至关重要,并应在合理范围内提供最大程度的辐射防护。为了避免低估镜片剂量,领圈剂量计是必要的,而防护眼镜后面的第三个剂量计对那些可能超过剂量限值的患者会有帮助。病人剂量的减少会相应减少工作人员的剂量。正确放置安装在天花板上的防护罩和尽量减小面部与玻璃之间的间隙是有效防护的关键。优化程序和设备,帮助保持与辐照区域的距离,防止仰视姿势,将大大降低镜头剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信