Rubi Troncoso C, Claudia Sepúlveda F, Evelyn Sepúlveda P, Camila Guzmán U, Marcela Morales G, Cecilia Tapia P
{"title":"[Evaluation of the Aspergillus Galactomannan ag VircliaR Monotest test as an alternative to Platelia™ Aspergillus EIA kit].","authors":"Rubi Troncoso C, Claudia Sepúlveda F, Evelyn Sepúlveda P, Camila Guzmán U, Marcela Morales G, Cecilia Tapia P","doi":"10.4067/s0716-10182022000200248","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Aspergillus Galactomannan Ag Virclia® (GMVClia) test is a monotest and automated galactomannan technique based on chemiluminescent immunoassay (CLIA).</p><p><strong>Aim: </strong>To evaluate the performance of the GM-VClia test in serum and bronchioalveolar lavage (BAL) samples previously processed with the Platelia ™ Aspergillus EIA kit (GM-Plat).</p><p><strong>Methods: </strong>56 samples of serum 40 from BAL (some of them with galactomaman determination in both samples), from patients with pulmonary diseases, hematological diseases, SLE, Covid-19 and tumors, among others, were studied. Thirteen patients had invasive aspergillosis (1 proven and 12 probable).</p><p><strong>Results: </strong>The correlation between both methods for serum and BAL was r = 0.8861 p < 0.0001 and r = 0.6368 p < 0.001, respectively. There was a global concordance of 67.7% (65/96), being 85.7% (48/56) in sera and 42.5.0% (14/49) in BAL. By raising the cut-off point in LBA by GM-VClia, the agreement increased to 85.7%.</p><p><strong>Conclusion: </strong>A greater correlation and concordance was observed in sera than in BAL. The GM-VClia kit had a higher sensitivity and NPV than the GM-Plat kit. The disadvantages of GM-VClia are the \"doubtful\" category, which makes interpretation difficult and that with the current cut-off points in LBA the correlation with GM-Plat is lower. The advantages are its greater sensitivity, ease of processing and faster results.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4067/s0716-10182022000200248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The Aspergillus Galactomannan Ag Virclia® (GMVClia) test is a monotest and automated galactomannan technique based on chemiluminescent immunoassay (CLIA).
Aim: To evaluate the performance of the GM-VClia test in serum and bronchioalveolar lavage (BAL) samples previously processed with the Platelia ™ Aspergillus EIA kit (GM-Plat).
Methods: 56 samples of serum 40 from BAL (some of them with galactomaman determination in both samples), from patients with pulmonary diseases, hematological diseases, SLE, Covid-19 and tumors, among others, were studied. Thirteen patients had invasive aspergillosis (1 proven and 12 probable).
Results: The correlation between both methods for serum and BAL was r = 0.8861 p < 0.0001 and r = 0.6368 p < 0.001, respectively. There was a global concordance of 67.7% (65/96), being 85.7% (48/56) in sera and 42.5.0% (14/49) in BAL. By raising the cut-off point in LBA by GM-VClia, the agreement increased to 85.7%.
Conclusion: A greater correlation and concordance was observed in sera than in BAL. The GM-VClia kit had a higher sensitivity and NPV than the GM-Plat kit. The disadvantages of GM-VClia are the "doubtful" category, which makes interpretation difficult and that with the current cut-off points in LBA the correlation with GM-Plat is lower. The advantages are its greater sensitivity, ease of processing and faster results.