An investigation of the efficacy of shear wave elastography in the characterization of benign and malignant liver lesions.

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Polish Journal of Radiology Pub Date : 2022-08-18 eCollection Date: 2022-01-01 DOI:10.5114/pjr.2022.119060
Suat Keskin, Ozan Babaoglu, Zeynep Keskin
{"title":"An investigation of the efficacy of shear wave elastography in the characterization of benign and malignant liver lesions.","authors":"Suat Keskin,&nbsp;Ozan Babaoglu,&nbsp;Zeynep Keskin","doi":"10.5114/pjr.2022.119060","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate whether shear wave elastography (SWE) examination, which has recently been proposed as an accessory radiological examination technique, is effective in characterizing focal liver lesions (FLLs).</p><p><strong>Material and methods: </strong>A total of 105 patients, comprising 48 males and 57 females, underwent SWE examination. The mean age of the patients was 53.31 ± 1.59 (age range 5-87) years. The SWE measurements were obtained from FLLs that were approximately 2 to 8 cm in depth in a box that was approximately 0.5 × 1 cm wide on an ultrasonography (USG) screen from approximately 2 different locations. Receiver operating characteristic (ROC) curve analysis was performed to determine the diagnostic SWE values in the differentiation of benign and malignant lesions. Sensitivity, specificity, and positive predictive and negative predictive values were calculated in the presence of significant limit values.</p><p><strong>Results: </strong>The SWE values, in kPa and m/s, in the malignant lesions were significantly higher than those in the benign lesions (<i>p</i> = 0.006, <i>p</i> = 0.011). In the ROC curve analysis, the cut-off value was calculated as 9.005 kPa in the differentiation of malignant lesions from benign lesions. The area under the ROC curve was calculated as 0.656 in the range of 0.551-0.761 with 95% reliability. Sensitivity was calculated as 64.2%, specificity as 61.5%, positive predictive value as 63%, and negative predictive value as 62.7%.</p><p><strong>Conclusions: </strong>In addition to providing little contribution to the differentiation of benign and malignant lesions, the SWE technique is thought to contribute to a certain extent, especially in suspected cases, during the diagnosis with cross-sectional methods.</p>","PeriodicalId":47128,"journal":{"name":"Polish Journal of Radiology","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2022-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/74/c9/PJR-87-47711.PMC9453240.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/pjr.2022.119060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To investigate whether shear wave elastography (SWE) examination, which has recently been proposed as an accessory radiological examination technique, is effective in characterizing focal liver lesions (FLLs).

Material and methods: A total of 105 patients, comprising 48 males and 57 females, underwent SWE examination. The mean age of the patients was 53.31 ± 1.59 (age range 5-87) years. The SWE measurements were obtained from FLLs that were approximately 2 to 8 cm in depth in a box that was approximately 0.5 × 1 cm wide on an ultrasonography (USG) screen from approximately 2 different locations. Receiver operating characteristic (ROC) curve analysis was performed to determine the diagnostic SWE values in the differentiation of benign and malignant lesions. Sensitivity, specificity, and positive predictive and negative predictive values were calculated in the presence of significant limit values.

Results: The SWE values, in kPa and m/s, in the malignant lesions were significantly higher than those in the benign lesions (p = 0.006, p = 0.011). In the ROC curve analysis, the cut-off value was calculated as 9.005 kPa in the differentiation of malignant lesions from benign lesions. The area under the ROC curve was calculated as 0.656 in the range of 0.551-0.761 with 95% reliability. Sensitivity was calculated as 64.2%, specificity as 61.5%, positive predictive value as 63%, and negative predictive value as 62.7%.

Conclusions: In addition to providing little contribution to the differentiation of benign and malignant lesions, the SWE technique is thought to contribute to a certain extent, especially in suspected cases, during the diagnosis with cross-sectional methods.

Abstract Image

Abstract Image

Abstract Image

横波弹性成像在肝良恶性病变诊断中的疗效研究。
目的:探讨最近被提议作为辅助放射检查技术的横波弹性成像(SWE)检查是否能有效地表征局灶性肝脏病变(fll)。材料与方法:105例患者行SWE检查,其中男48例,女57例。患者平均年龄53.31±1.59岁(年龄5 ~ 87岁)。SWE测量是在超声(USG)屏幕上从大约2个不同位置的约2至8厘米深的盒子中获得的,盒子宽约0.5 × 1厘米。进行受试者工作特征(ROC)曲线分析,确定SWE在良恶性病变鉴别中的诊断价值。敏感性、特异性、阳性预测值和阴性预测值在存在显著极限值的情况下计算。结果:恶性病变的SWE值(kPa、m/s)显著高于良性病变(p = 0.006、p = 0.011)。在ROC曲线分析中,计算出良性与恶性病变鉴别的截止值为9.005 kPa。在0.551-0.761范围内,ROC曲线下面积计算为0.656,信度为95%。敏感性为64.2%,特异性为61.5%,阳性预测值为63%,阴性预测值为62.7%。结论:除了对良恶性病变的鉴别贡献不大外,SWE技术在横断面方法的诊断中有一定的贡献,特别是在疑似病例中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Polish Journal of Radiology
Polish Journal of Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信