{"title":"Influencing the selectivity of grafted anion exchangers utilizing the solubility of the radical initiator during the graft process","authors":"Achim Kaltz,&nbsp;Lea Bohra,&nbsp;Jonathan S. Tripp,&nbsp;Andreas Seubert","doi":"10.1016/j.acax.2019.100019","DOIUrl":null,"url":null,"abstract":"<div><p>A previously published radical graft-functionalization method for the synthesis of high performance anion exchangers was further investigated to control the capacity and selectivity of the exchangers. Using a hydrophobic radical initiator instead of a hydrophilic one diminished the influence of rivaling homopolymerization of monomer during the functionalization step. Instead of only generating monomer radicals in free solution the radicals are ideally generated on top of the PS/DVB surface. However, in both cases the selectivity factors of polarizable anions bromide and nitrate in relation to chloride increased strongly with increasing capacity of the exchanger. Higher exchanger capacities could lead to coelution of bromide and/or nitrate with other analytes such as sulfate or phosphate when using the eluent as proposed in this work. By variation of the organic solvent used for functionalization it was possible to remove both the rivaling homopolymerization and the strong influence of the capacity on the selectivity. With increasing solubility of the hydrophobic radical initiator in the organic solvent the influence of the homopolymerization and the influence on the selectivity factor of bromide and nitrate decreased. Additionally, a change of bromate selectivity factor could be observed. The bromate signal is shifted closer towards the chloride signal. However, with increasing solubility of the radical initiator in the organic solvent the observed capacity of the exchangers decreases linearly, resulting in higher amounts of monomer needed for functionalization.</p></div>","PeriodicalId":241,"journal":{"name":"Analytica Chimica Acta: X","volume":"2 ","pages":"Article 100019"},"PeriodicalIF":2.5000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.acax.2019.100019","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590134619300155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

Abstract

A previously published radical graft-functionalization method for the synthesis of high performance anion exchangers was further investigated to control the capacity and selectivity of the exchangers. Using a hydrophobic radical initiator instead of a hydrophilic one diminished the influence of rivaling homopolymerization of monomer during the functionalization step. Instead of only generating monomer radicals in free solution the radicals are ideally generated on top of the PS/DVB surface. However, in both cases the selectivity factors of polarizable anions bromide and nitrate in relation to chloride increased strongly with increasing capacity of the exchanger. Higher exchanger capacities could lead to coelution of bromide and/or nitrate with other analytes such as sulfate or phosphate when using the eluent as proposed in this work. By variation of the organic solvent used for functionalization it was possible to remove both the rivaling homopolymerization and the strong influence of the capacity on the selectivity. With increasing solubility of the hydrophobic radical initiator in the organic solvent the influence of the homopolymerization and the influence on the selectivity factor of bromide and nitrate decreased. Additionally, a change of bromate selectivity factor could be observed. The bromate signal is shifted closer towards the chloride signal. However, with increasing solubility of the radical initiator in the organic solvent the observed capacity of the exchangers decreases linearly, resulting in higher amounts of monomer needed for functionalization.

Abstract Image

利用自由基引发剂在接枝过程中的溶解度影响接枝阴离子交换剂的选择性
进一步研究了先前发表的一种用于合成高性能阴离子交换剂的自由基接枝功能化方法,以控制交换剂的容量和选择性。用疏水自由基引发剂代替亲水自由基引发剂,降低了单体在官能化过程中竞争均聚的影响。自由基不是只在自由溶液中产生单体自由基,理想情况下自由基是在PS/DVB表面上产生的。然而,在这两种情况下,可极化阴离子溴化物和硝酸盐相对于氯化物的选择性因子随着交换剂容量的增加而显著增加。更高的交换容量可能导致溴化物和/或硝酸盐与其他分析物如硫酸盐或磷酸盐在使用本工作中提出的洗脱液时共洗脱。通过改变用于功能化的有机溶剂,可以消除竞争性均聚和容量对选择性的强烈影响。随着疏水自由基引发剂在有机溶剂中溶解度的增加,均聚合的影响以及对溴化物和硝酸盐选择性因子的影响减小。此外,还观察到溴酸盐选择性因子的变化。溴酸盐信号向氯离子信号移动。然而,随着自由基引发剂在有机溶剂中的溶解度的增加,观察到的交换剂容量线性下降,导致官能化所需的单体量增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytica Chimica Acta: X
Analytica Chimica Acta: X Chemistry-Analytical Chemistry
自引率
0.00%
发文量
3
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信