A Convenient RP-HPLC Method for Assay Bioactivities of Angiotensin I-Converting Enzyme Inhibitory Peptides.

ISRN biotechnology Pub Date : 2012-10-21 eCollection Date: 2013-01-01 DOI:10.5402/2013/453910
Wei Wang, Nan Wang, Yu Zhang, Zheng Cai, Qihe Chen, Guoqing He
{"title":"A Convenient RP-HPLC Method for Assay Bioactivities of Angiotensin I-Converting Enzyme Inhibitory Peptides.","authors":"Wei Wang,&nbsp;Nan Wang,&nbsp;Yu Zhang,&nbsp;Zheng Cai,&nbsp;Qihe Chen,&nbsp;Guoqing He","doi":"10.5402/2013/453910","DOIUrl":null,"url":null,"abstract":"<p><p>A convenient and accurate reversed-phase high-performance liquid chromatography (RP-HPLC) method for angiotensin I-converting enzyme inhibitory peptides assay was described in this paper. The mobile phase consisted of 70% A (0.05% TFA and 0.05% triethylamine in water, pH = 2.9-3.3) and 30% B (100% acetonitrile) using an Isogradient program. The flow rate was 0.5 mL/min. The absorb wavelength was 226.5 nm; the column temperature was controlled at 25°C. This method for angiotensin I-converting enzyme inhibitory peptides assay was convenient for the Iso-gradient program. The accuracy of the RT-HPLC method was verified by analyzing ACE inhibitory activity of the hydrolysate peptides of silkworm pupae protein, and the results showed that the RT-HPLC method was available for exploring new source of angiotensin I-converting enzyme inhibitory peptides rapidly and veraciously. </p>","PeriodicalId":90878,"journal":{"name":"ISRN biotechnology","volume":"2013 ","pages":"453910"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5402/2013/453910","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2013/453910","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

A convenient and accurate reversed-phase high-performance liquid chromatography (RP-HPLC) method for angiotensin I-converting enzyme inhibitory peptides assay was described in this paper. The mobile phase consisted of 70% A (0.05% TFA and 0.05% triethylamine in water, pH = 2.9-3.3) and 30% B (100% acetonitrile) using an Isogradient program. The flow rate was 0.5 mL/min. The absorb wavelength was 226.5 nm; the column temperature was controlled at 25°C. This method for angiotensin I-converting enzyme inhibitory peptides assay was convenient for the Iso-gradient program. The accuracy of the RT-HPLC method was verified by analyzing ACE inhibitory activity of the hydrolysate peptides of silkworm pupae protein, and the results showed that the RT-HPLC method was available for exploring new source of angiotensin I-converting enzyme inhibitory peptides rapidly and veraciously.

Abstract Image

Abstract Image

Abstract Image

一种简便的反相高效液相色谱法测定血管紧张素i转换酶抑制肽的生物活性。
本文建立了一种简便、准确的反相高效液相色谱(RP-HPLC)测定血管紧张素i转换酶抑制肽的方法。流动相为70% A (0.05% TFA和0.05%三乙胺水溶液,pH = 2.9-3.3)和30% B(100%乙腈),采用等梯度程序。流速0.5 mL/min。吸收波长为226.5 nm;柱温控制在25℃。该方法用于血管紧张素i转换酶抑制肽的测定,便于进行等梯度程序。通过分析蚕蛹蛋白水解肽的ACE抑制活性,验证了RT-HPLC方法的准确性,结果表明,RT-HPLC方法可快速准确地寻找血管紧张素i转换酶抑制肽的新来源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书