Development of biological oxygen demand biosensor for monitoring the fermentation industry effluent.

ISRN biotechnology Pub Date : 2012-11-27 eCollection Date: 2013-01-01 DOI:10.5402/2013/236062
Neelam Verma, Ashish Kumar Singh
{"title":"Development of biological oxygen demand biosensor for monitoring the fermentation industry effluent.","authors":"Neelam Verma,&nbsp;Ashish Kumar Singh","doi":"10.5402/2013/236062","DOIUrl":null,"url":null,"abstract":"<p><p>A biosensor was developed for the determination of BOD value of fermentation industry effluent. The developed biosensor was fabricated by immobilizing the microbial consortium on cellulose acetate (CA) membrane in close proximity to a DO probe electrode. The microbial consortium was harvested from the fermentation industry effluent. The BOD biosensor was calibrated by using a solution containing the equivalent amount of glucose/glutamic acid (GGA) as a standard sample solution. The response time was optimized by immobilizing different concentrations of cell biomass on CA membrane. Once the response time was optimized, it was used for determination of BOD of fermentation industry effluent. For analysis of fermentation industry effluent, the response time was observed 7 minutes with detection limit 1 mg/L. Good linear range with GGA standard solution was observed, R (2) 0.99 with relative standard deviation (RSD) <%. The observed BOD value by biosensor showed a good comparison with the conventional method for the determination of BOD. </p>","PeriodicalId":90878,"journal":{"name":"ISRN biotechnology","volume":"2013 ","pages":"236062"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5402/2013/236062","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2013/236062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

A biosensor was developed for the determination of BOD value of fermentation industry effluent. The developed biosensor was fabricated by immobilizing the microbial consortium on cellulose acetate (CA) membrane in close proximity to a DO probe electrode. The microbial consortium was harvested from the fermentation industry effluent. The BOD biosensor was calibrated by using a solution containing the equivalent amount of glucose/glutamic acid (GGA) as a standard sample solution. The response time was optimized by immobilizing different concentrations of cell biomass on CA membrane. Once the response time was optimized, it was used for determination of BOD of fermentation industry effluent. For analysis of fermentation industry effluent, the response time was observed 7 minutes with detection limit 1 mg/L. Good linear range with GGA standard solution was observed, R (2) 0.99 with relative standard deviation (RSD) <%. The observed BOD value by biosensor showed a good comparison with the conventional method for the determination of BOD.

Abstract Image

Abstract Image

用于发酵工业废水监测的生物需氧量传感器的研制。
研制了一种用于发酵工业废水生化需氧量测定的生物传感器。所开发的生物传感器是通过将微生物财团固定在醋酸纤维素(CA)膜上,靠近DO探针电极来制备的。微生物联合体是从发酵工业废水中收获的。采用含有等量葡萄糖/谷氨酸(GGA)的溶液作为标准样品溶液,对BOD生物传感器进行校准。通过在CA膜上固定不同浓度的细胞生物量,优化了反应时间。优化反应时间后,将其用于发酵工业废水生化需氧量的测定。对发酵工业废水进行分析,反应时间为7分钟,检出限为1 mg/L。与GGA标准溶液线性范围良好,相对标准偏差(RSD) R(2) 0.99。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书