Radiostereometric analysis of sacroiliac joint movement and outcomes of pelvic joint fusion.

Thomas Johan Kibsgård
{"title":"Radiostereometric analysis of sacroiliac joint movement and outcomes of pelvic joint fusion.","authors":"Thomas Johan Kibsgård","doi":"10.3109/17453674.2015.1022707","DOIUrl":null,"url":null,"abstract":"Background Different techniques have been used to quantify the movement of sacroiliac (SI) joints. These include radiostereometric analysis (RSA), but the accuracy and precision of this method have not been properly evaluated and it is unclear how many markers are required and where they should be placed to achieve proper accuracy and precision. Purpose The purpose of this study was to test accuracy and precision of RSA, applied to the SI joint, in a phantom model and in patients. Methods We used a plastic phantom attached to a micrometer to obtain a true value of the movement of the SI joint and compared this value with the measured value obtained by RSA; the difference represented the accuracy. The precision of the system was measured by double examination in the phantom and in six patients, and was expressed by a limit of significance (LOS). We analyzed different marker distributions to find optimal marker placement and number of markers needed. Results The accuracy was high and we identified no systematic errors. The precision of the phantom was high with a LOS less than 0.25 and 0.16 mm for all directions, and in patients, the precision was less than 0.71 for rotations and 0.47 mm translations. No markers were needed in the pubic symphysis to obtain good precision. Conclusions The accuracy and precision are high when RSA is used to measure movement in the SI joint and support the use of RSA in research of SI joint motion.","PeriodicalId":87168,"journal":{"name":"Acta orthopaedica. Supplementum","volume":"86 359","pages":"1-43"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/17453674.2015.1022707","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica. Supplementum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/17453674.2015.1022707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Background Different techniques have been used to quantify the movement of sacroiliac (SI) joints. These include radiostereometric analysis (RSA), but the accuracy and precision of this method have not been properly evaluated and it is unclear how many markers are required and where they should be placed to achieve proper accuracy and precision. Purpose The purpose of this study was to test accuracy and precision of RSA, applied to the SI joint, in a phantom model and in patients. Methods We used a plastic phantom attached to a micrometer to obtain a true value of the movement of the SI joint and compared this value with the measured value obtained by RSA; the difference represented the accuracy. The precision of the system was measured by double examination in the phantom and in six patients, and was expressed by a limit of significance (LOS). We analyzed different marker distributions to find optimal marker placement and number of markers needed. Results The accuracy was high and we identified no systematic errors. The precision of the phantom was high with a LOS less than 0.25 and 0.16 mm for all directions, and in patients, the precision was less than 0.71 for rotations and 0.47 mm translations. No markers were needed in the pubic symphysis to obtain good precision. Conclusions The accuracy and precision are high when RSA is used to measure movement in the SI joint and support the use of RSA in research of SI joint motion.
骶髂关节运动和骨盆关节融合结果的放射立体分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信