[Examination of the mechanical properties of zirconia and porcelain blocks after grinding with smooth and coarse diamond burrs].

Refu'at ha-peh veha-shinayim (1993) Pub Date : 2014-04-01
S Shemer, A Hendler, R Pilo, E Weiss, M Perez-Davidi
{"title":"[Examination of the mechanical properties of zirconia and porcelain blocks after grinding with smooth and coarse diamond burrs].","authors":"S Shemer,&nbsp;A Hendler,&nbsp;R Pilo,&nbsp;E Weiss,&nbsp;M Perez-Davidi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>Porcelain and Zirconia are widely used materials in oral rehabilitation for fixed partial dentures, FPD. Among many important properties, A FPD should be able to resist bite forces, the harsh oral environment and to remain intact for a long period of time. When coming back from the dental laboratory, the mechanical properties of the FPD are optimal. But it is not uncommon for the dentist to perform a machining procedures on the restoration in order to achieve good fitting to the prepared teeth. In most cases these modifications are made using high speed dental hand piece, and diamond burs. The surface integrity of the restoration is an important parameter that influences on the restoration strength and durability. The more smooth the restoration surface is, it is less prone to fracture, and is less prone to coloring and plaque retention. Therefore, every modification the dentist makes on the restoration is not recommended. In some cases, the adjustments are made on a FPD which is already cemented to the teeth. If the teeth are vital, the implications of the machining of the restoration are even more destructive. As a result of the friction between the bur and the restoration, the temperature rises. There is a risk of pulp necrosis in temperature above 42 degrees C. The purpose of this study is to compare the mechanical properties of Zirconia and Porcelain blocks after grinding with smooth burs made in a new technology, Magic touch, Strauss co. (Ranana, Israel) and coarse burs.</p><p><strong>Materials and methods: </strong>blocks of Porcelain MARK II for CEREC (VIDENT), and Zirconia IPS e.max ZirCAD (Ivoclar Vivadent) were sliced to slices of 1mm and underwent drilling using the two kinds of burs, using thermocoupling--Almemo, Holzkirchen, Germany. So that the rise in temperature was measured through the drilling. Blocks of Porcelain and Zirconia were machined with the two kinds of burs, and their surface roughness was examined with Mitutoyo Surftest 402 Profilometer. Further examination was made with SEM micrographs.</p><p><strong>Results: </strong>the samples machined with Magic touch burs, both on Porcelain and Zirconia, were significantly smoother than the samples machined with coarse burs (P 0.05). There was no significant rise in temperature (above 42 degrees C) using both kind of burs, on both Porcelain and Zirconia. The SEM microscopy demonstrates smoother surface of the porcelain and Zirconia which were grinded with Magic touch burs.</p><p><strong>Conclusions: </strong>Magic touch diamond burs, enables the dentist to perform fit adjustments on Porcelain or Zirconia FPD, leaving the restoration with minimum surface roughness, without elevating the temperature to high values, permitting both the tooth and the restoration to remain strong and durable for a longer period of time.</p>","PeriodicalId":82453,"journal":{"name":"Refu'at ha-peh veha-shinayim (1993)","volume":"31 2","pages":"31-9, 87"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Refu'at ha-peh veha-shinayim (1993)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Unlabelled: Porcelain and Zirconia are widely used materials in oral rehabilitation for fixed partial dentures, FPD. Among many important properties, A FPD should be able to resist bite forces, the harsh oral environment and to remain intact for a long period of time. When coming back from the dental laboratory, the mechanical properties of the FPD are optimal. But it is not uncommon for the dentist to perform a machining procedures on the restoration in order to achieve good fitting to the prepared teeth. In most cases these modifications are made using high speed dental hand piece, and diamond burs. The surface integrity of the restoration is an important parameter that influences on the restoration strength and durability. The more smooth the restoration surface is, it is less prone to fracture, and is less prone to coloring and plaque retention. Therefore, every modification the dentist makes on the restoration is not recommended. In some cases, the adjustments are made on a FPD which is already cemented to the teeth. If the teeth are vital, the implications of the machining of the restoration are even more destructive. As a result of the friction between the bur and the restoration, the temperature rises. There is a risk of pulp necrosis in temperature above 42 degrees C. The purpose of this study is to compare the mechanical properties of Zirconia and Porcelain blocks after grinding with smooth burs made in a new technology, Magic touch, Strauss co. (Ranana, Israel) and coarse burs.

Materials and methods: blocks of Porcelain MARK II for CEREC (VIDENT), and Zirconia IPS e.max ZirCAD (Ivoclar Vivadent) were sliced to slices of 1mm and underwent drilling using the two kinds of burs, using thermocoupling--Almemo, Holzkirchen, Germany. So that the rise in temperature was measured through the drilling. Blocks of Porcelain and Zirconia were machined with the two kinds of burs, and their surface roughness was examined with Mitutoyo Surftest 402 Profilometer. Further examination was made with SEM micrographs.

Results: the samples machined with Magic touch burs, both on Porcelain and Zirconia, were significantly smoother than the samples machined with coarse burs (P 0.05). There was no significant rise in temperature (above 42 degrees C) using both kind of burs, on both Porcelain and Zirconia. The SEM microscopy demonstrates smoother surface of the porcelain and Zirconia which were grinded with Magic touch burs.

Conclusions: Magic touch diamond burs, enables the dentist to perform fit adjustments on Porcelain or Zirconia FPD, leaving the restoration with minimum surface roughness, without elevating the temperature to high values, permitting both the tooth and the restoration to remain strong and durable for a longer period of time.

[用金刚石毛刺磨平和磨粗后氧化锆和陶瓷块的力学性能检验]。
未标记:陶瓷和氧化锆是口腔修复中广泛使用的材料,用于固定局部义齿,FPD。在许多重要的性能中,FPD应该能够抵抗咬合力,恶劣的口腔环境,并长时间保持完整。当从牙科实验室回来时,FPD的机械性能是最佳的。但是,为了与预备好的牙齿很好地贴合,牙医对修复体进行机械加工的情况并不少见。在大多数情况下,这些修改是使用高速牙手片和金刚石毛刺。修复体的表面完整性是影响修复体强度和耐久性的重要参数。修复面越光滑,就越不容易骨折,也就越不容易着色和菌斑滞留。因此,不建议牙医对修复体进行任何修改。在某些情况下,调整是在已经粘合到牙齿上的FPD上进行的。如果牙齿是至关重要的,机械加工修复的影响甚至更具破坏性。由于钢钎和修复体之间的摩擦,温度升高。在42摄氏度以上的温度下存在牙髓坏死的风险。本研究的目的是比较使用新技术Magic touch, Strauss公司(Ranana, Israel)制造的光滑毛刺和粗糙毛刺研磨后的氧化锆和陶瓷块的机械性能。材料和方法:将陶瓷MARK II(用于CEREC) (VIDENT)和Zirconia IPS e.max ZirCAD (Ivoclar Vivadent)块切成1mm的薄片,并使用两种毛刺进行钻孔,使用热偶联-Almemo, Holzkirchen,德国。所以温度的上升是通过钻孔来测量的。用两种毛刺加工瓷块和氧化锆块,并用Mitutoyo Surftest 402型轮廓仪检测其表面粗糙度。用扫描电镜进一步检查。结果:用Magic touch毛刺加工的陶瓷和氧化锆表面均比用粗毛刺加工的表面光滑(P < 0.05)。在陶瓷和氧化锆上使用这两种毛刺都没有明显的温度升高(超过42摄氏度)。扫描电镜观察表明,用Magic触摸毛刺研磨的陶瓷和氧化锆表面更光滑。结论:神奇触摸金刚石毛刺,使牙医能够在瓷或氧化锆FPD上进行贴合调整,使修复体具有最小的表面粗糙度,而无需将温度升高到很高的值,从而使牙齿和修复体在更长的时间内保持坚固耐用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书