A survey of organ equivalent and effective doses from diagnostic radiology procedures.

ISRN radiology Pub Date : 2012-09-06 eCollection Date: 2013-01-01 DOI:10.5402/2013/204346
Ernest K Osei, Johnson Darko
{"title":"A survey of organ equivalent and effective doses from diagnostic radiology procedures.","authors":"Ernest K Osei, Johnson Darko","doi":"10.5402/2013/204346","DOIUrl":null,"url":null,"abstract":"<p><p>The quantification of radiation risks associated with radiological examinations has been a subject of interest with the increased use of X-rays. Effective dose, which is a risk-weighted measure of radiation to organs in the body associated with radiological examination, is considered a good indicator of radiological risk. We have therefore investigated patient effective doses from radiological examinations. Organ and effective doses were estimated for 94 patients who underwent computed tomography examinations and for 338 patients who had conventional radiography examinations. The OrgDose (version 2) program was used for the estimation of effective doses. The tube potential ranges: 57 kVp to 138 kVp depending on the examination and patient size. The entrance surface doses have a wide range even for the same examination: 0.44-10.31 mGy (abdomen) and 0.66-16.08 mGy (lumbar spine) and the corresponding effective dose ranges 0.025-0.77 mSv and 0.025-0.95 mSv respectively. Effective dose for adult abdomen-pelvic CT examinations ranges 5.4-19.8 mSv with a mean of 13.6 mSv and for pediatrics ranges 2.1-5.5 mSv with a mean of 2.7 mSv. The mean effective dose for adult chest and head CT examinations are 7.9 and 1.8 mSv respectively and for pediatrics are 1.7 and 1.1 mSv. </p>","PeriodicalId":90195,"journal":{"name":"ISRN radiology","volume":"2013 ","pages":"204346"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4045519/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2013/204346","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The quantification of radiation risks associated with radiological examinations has been a subject of interest with the increased use of X-rays. Effective dose, which is a risk-weighted measure of radiation to organs in the body associated with radiological examination, is considered a good indicator of radiological risk. We have therefore investigated patient effective doses from radiological examinations. Organ and effective doses were estimated for 94 patients who underwent computed tomography examinations and for 338 patients who had conventional radiography examinations. The OrgDose (version 2) program was used for the estimation of effective doses. The tube potential ranges: 57 kVp to 138 kVp depending on the examination and patient size. The entrance surface doses have a wide range even for the same examination: 0.44-10.31 mGy (abdomen) and 0.66-16.08 mGy (lumbar spine) and the corresponding effective dose ranges 0.025-0.77 mSv and 0.025-0.95 mSv respectively. Effective dose for adult abdomen-pelvic CT examinations ranges 5.4-19.8 mSv with a mean of 13.6 mSv and for pediatrics ranges 2.1-5.5 mSv with a mean of 2.7 mSv. The mean effective dose for adult chest and head CT examinations are 7.9 and 1.8 mSv respectively and for pediatrics are 1.7 and 1.1 mSv.

放射诊断程序的器官当量和有效剂量调查。
随着 X 射线使用量的增加,与放射检查相关的辐射风险量化一直是人们关注的主题。有效剂量是放射检查对人体器官辐射的风险加权测量值,被认为是放射风险的良好指标。因此,我们对放射检查产生的患者有效剂量进行了调查。我们对 94 名接受计算机断层扫描检查的患者和 338 名接受传统放射检查的患者的器官剂量和有效剂量进行了估算。有效剂量的估算使用了 OrgDose(版本 2)程序。射线管电位范围为57 kVp 至 138 kVp,具体取决于检查项目和患者体型。即使是同一次检查,入口表面剂量的范围也很大:0.44-10.31 mGy(腹部)和 0.66-16.08 mGy(腰椎),相应的有效剂量范围分别为 0.025-0.77 mSv 和 0.025-0.95 mSv。成人腹部-骨盆 CT 检查的有效剂量范围为 5.4-19.8 mSv,平均为 13.6 mSv;儿科检查的有效剂量范围为 2.1-5.5 mSv,平均为 2.7 mSv。成人胸部和头部 CT 检查的平均有效剂量分别为 7.9 mSv 和 1.8 mSv,儿科为 1.7 mSv 和 1.1 mSv。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书