Correlation of trochanter-shaft angle in selection of entry site in antegrade intramedullary femoral nail.

ISRN orthopedics Pub Date : 2012-05-17 eCollection Date: 2012-01-01 DOI:10.5402/2012/431374
O P Lakhwani
{"title":"Correlation of trochanter-shaft angle in selection of entry site in antegrade intramedullary femoral nail.","authors":"O P Lakhwani","doi":"10.5402/2012/431374","DOIUrl":null,"url":null,"abstract":"<p><p>Background. Selection of entry point for nail insertion is controversial and lack firm anatomical basis. The study is done to analyze the proximal anthropometry of femur and measure the Trochanter-Shaft Angle to find its relation and significance in selection of entry point for antegrade uniplanar femoral nail. Materials and Methods. Study involves the measurement of trochanter-shaft angle and other anthropometric measurements on 50 dry femora and on digital radiogram. Results. Trochanter-Shaft angle ranges between 5-17 degrees in anthropometric study and 4-14 degrees in radiological study. Over all in 27 cases (54%), exit points of reamur fall in the middle quadrant in sagittal and coronal plane, which corresponds to the T-S angle of 6-12 degrees. Discussion and Conclusion. Proximal femoral Anthropometry and Trochanter-shaft angle is variable; hence it is difficult to fix any anatomical point as a universal entry point for antegrade femoral nail insertion. Trochanter shaft angle (TSA) can be well accessed radiologically and serve as a guide for selection of proper entry point.for safe nail insertion. Clinical Relevance. Individual variations in the proximal femur anatomy for safe nail insertion can be correlated with Trochanter shaft angle to serve safe entry site. </p>","PeriodicalId":89787,"journal":{"name":"ISRN orthopedics","volume":"2012 ","pages":"431374"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5402/2012/431374","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2012/431374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Background. Selection of entry point for nail insertion is controversial and lack firm anatomical basis. The study is done to analyze the proximal anthropometry of femur and measure the Trochanter-Shaft Angle to find its relation and significance in selection of entry point for antegrade uniplanar femoral nail. Materials and Methods. Study involves the measurement of trochanter-shaft angle and other anthropometric measurements on 50 dry femora and on digital radiogram. Results. Trochanter-Shaft angle ranges between 5-17 degrees in anthropometric study and 4-14 degrees in radiological study. Over all in 27 cases (54%), exit points of reamur fall in the middle quadrant in sagittal and coronal plane, which corresponds to the T-S angle of 6-12 degrees. Discussion and Conclusion. Proximal femoral Anthropometry and Trochanter-shaft angle is variable; hence it is difficult to fix any anatomical point as a universal entry point for antegrade femoral nail insertion. Trochanter shaft angle (TSA) can be well accessed radiologically and serve as a guide for selection of proper entry point.for safe nail insertion. Clinical Relevance. Individual variations in the proximal femur anatomy for safe nail insertion can be correlated with Trochanter shaft angle to serve safe entry site.

Abstract Image

Abstract Image

Abstract Image

股骨转子轴角与顺行髓内钉入路选择的关系。
背景。钉入点的选择是有争议的,缺乏坚实的解剖学基础。分析股骨近端人体测量数据,测量股骨粗隆轴角,探讨其在顺行单平面股内钉入点选择中的关系和意义。材料与方法。研究包括对50根干股骨进行粗隆轴角测量和其他人体测量,并进行数字x线摄影。结果。股骨粗隆-轴角在人体测量学研究中为5-17度,在放射学研究中为4-14度。27例(54%)的瘤壁出口点位于矢状面和冠状面中象限,对应的T-S角为6-12度。讨论与结论。股骨近端人体测量和股骨粗隆角是可变的;因此,很难确定任何解剖点作为顺行股内钉插入的通用切入点。转子轴角(TSA)可以很好地进入放射学,并可作为选择合适进入点的指导。为了安全插入指甲。临床相关性。股骨近端解剖结构的个体差异可与转子轴角度相关,以提供安全的入钉位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信