The Role of ECG-Gated CT in Patients with Bicuspid Aortic Valve Replacement: New Perspectives in Short- and Long-Term Followup.

ISRN radiology Pub Date : 2012-10-23 eCollection Date: 2013-01-01 DOI:10.5402/2013/826073
Massimiliano Sperandio, Chiara Arganini, Alessio Bindi, Armando Fusco, Carlo Olevano, Fabio Bertoldo, Andrea Romagnoli, Luigi Chiariello, Giovanni Simonetti
{"title":"The Role of ECG-Gated CT in Patients with Bicuspid Aortic Valve Replacement: New Perspectives in Short- and Long-Term Followup.","authors":"Massimiliano Sperandio,&nbsp;Chiara Arganini,&nbsp;Alessio Bindi,&nbsp;Armando Fusco,&nbsp;Carlo Olevano,&nbsp;Fabio Bertoldo,&nbsp;Andrea Romagnoli,&nbsp;Luigi Chiariello,&nbsp;Giovanni Simonetti","doi":"10.5402/2013/826073","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of our study was to compare the results of the TTE (transthoracic echocardiography) with the results obtained by the ECG-gated 64 slices CT during the followup of patients with bicuspid aortic valve (BAV), after aortic valve replacement; in particular we evaluated the aortic root and the ascending aorta looking for a new algorithm in the followup of these patients. From January 1999 to December 2009 our attention was focused on 67 patients with isolated surgical substitution of aortic valve; after dismissal they were strictly observed. During the period between May and September 2010, these patients underwent their last evaluation, and clinical exams, ECG, TTE, and an ECG-gated-MDCT were performed. At followup TTE results showed an aortic root of 36.7 ± 4 mm and an ascending aorta of 39.6 ± 4.8 mm. ECG- gated CT showed an aortic root of 37.9 ± 5.5 mm and an ascending aorta of 43.1 ± 5.2. The comparison between preoperative and postoperative TTE shows a significant long-term dilatation of the ascending aorta while the aortic root diameter seems to be stable. ECG-gated CT confirms the stability of the aortic root diameter (38.2 ± 5.3 mm versus 37.9 ± 5.5  mm; <0.0001) and the increasing diameter value of the ascending aorta (40.2 ± 3.9 mm versus 43.1 ± 5.2 mm; P = 0.0156). Due to the different findings between CT and TTE studies, ECG-gated CT should no longer be considered as a complementary exam in the followup of patients with BAV, but as a fundamental role since it is a real necessity. </p>","PeriodicalId":90195,"journal":{"name":"ISRN radiology","volume":"2013 ","pages":"826073"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4045515/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2013/826073","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The aim of our study was to compare the results of the TTE (transthoracic echocardiography) with the results obtained by the ECG-gated 64 slices CT during the followup of patients with bicuspid aortic valve (BAV), after aortic valve replacement; in particular we evaluated the aortic root and the ascending aorta looking for a new algorithm in the followup of these patients. From January 1999 to December 2009 our attention was focused on 67 patients with isolated surgical substitution of aortic valve; after dismissal they were strictly observed. During the period between May and September 2010, these patients underwent their last evaluation, and clinical exams, ECG, TTE, and an ECG-gated-MDCT were performed. At followup TTE results showed an aortic root of 36.7 ± 4 mm and an ascending aorta of 39.6 ± 4.8 mm. ECG- gated CT showed an aortic root of 37.9 ± 5.5 mm and an ascending aorta of 43.1 ± 5.2. The comparison between preoperative and postoperative TTE shows a significant long-term dilatation of the ascending aorta while the aortic root diameter seems to be stable. ECG-gated CT confirms the stability of the aortic root diameter (38.2 ± 5.3 mm versus 37.9 ± 5.5  mm; <0.0001) and the increasing diameter value of the ascending aorta (40.2 ± 3.9 mm versus 43.1 ± 5.2 mm; P = 0.0156). Due to the different findings between CT and TTE studies, ECG-gated CT should no longer be considered as a complementary exam in the followup of patients with BAV, but as a fundamental role since it is a real necessity.

Abstract Image

心电图门控CT在二尖瓣主动脉瓣置换术中的作用:短期和长期随访的新视角。
本研究的目的是比较二尖瓣主动脉瓣置换术后经胸超声心动图(TTE)与心电图门控64层CT的随访结果;特别地,我们评估了主动脉根部和升主动脉,在这些患者的随访中寻找一种新的算法。从1999年1月到2009年12月,我们的注意力集中在67例主动脉瓣置换术患者;下课后,他们被严格遵守。在2010年5月至9月期间,这些患者进行了最后一次评估,并进行了临床检查,心电图,TTE和心电图门控mdct。TTE随访显示主动脉根长36.7±4 mm,升主动脉长39.6±4.8 mm。心电图门控CT显示主动脉根长37.9±5.5 mm,升主动脉长43.1±5.2 mm。术前与术后TTE比较显示升主动脉长期明显扩张,而主动脉根径似乎稳定。心电图门控CT证实主动脉根直径稳定(38.2±5.3 mm vs 37.9±5.5 mm;
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书