Trilogy-constrained acetabular component for recurrent dislocation.

ISRN orthopedics Pub Date : 2013-01-10 eCollection Date: 2013-01-01 DOI:10.1155/2013/629201
Annette Vest Andersen, Anne Grete Kjersgaard, Søren Solgaard
{"title":"Trilogy-constrained acetabular component for recurrent dislocation.","authors":"Annette Vest Andersen,&nbsp;Anne Grete Kjersgaard,&nbsp;Søren Solgaard","doi":"10.1155/2013/629201","DOIUrl":null,"url":null,"abstract":"<p><p>32 patients received a Trilogy- or Trilogy-Longevity-constrained acetabular liner for recurrent dislocations after total hip replacement. The constrained liner was inserted into a well-fixed Trilogy acetabular shell with snap fit. At 1.8-year followup (range 3-63 months), 4 patients had suffered further dislocation(s) (12%), and one patient had revision surgery for a loosened acetabular shell. Radiologic evaluation detected no definitively loose components, but one patient with progressing radiolucent lines around the femoral component and one patient with an acetabular cyst were found, as well as a patient with a loose locking ring (but otherwise no failure). The nineteen patients who were available for the present followup had a mean Harris Hip Score of 81. The constrained liner is an effective method of dealing with recurrent dislocations in well-fixed components. </p>","PeriodicalId":89787,"journal":{"name":"ISRN orthopedics","volume":"2013 ","pages":"629201"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2013/629201","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2013/629201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

32 patients received a Trilogy- or Trilogy-Longevity-constrained acetabular liner for recurrent dislocations after total hip replacement. The constrained liner was inserted into a well-fixed Trilogy acetabular shell with snap fit. At 1.8-year followup (range 3-63 months), 4 patients had suffered further dislocation(s) (12%), and one patient had revision surgery for a loosened acetabular shell. Radiologic evaluation detected no definitively loose components, but one patient with progressing radiolucent lines around the femoral component and one patient with an acetabular cyst were found, as well as a patient with a loose locking ring (but otherwise no failure). The nineteen patients who were available for the present followup had a mean Harris Hip Score of 81. The constrained liner is an effective method of dealing with recurrent dislocations in well-fixed components.

Abstract Image

Abstract Image

髋臼三段式复位复位治疗复发性脱位。
32例患者在全髋关节置换术后复发性脱位接受了髋臼三部曲或三部曲-寿命约束衬垫。将受约束的内钉插入固定良好的Trilogy髋臼壳内。在1.8年的随访中(3-63个月),4例患者发生进一步脱位(12%),1例患者因髋臼壳松动进行了翻修手术。放射学评估没有发现明确的松动部件,但发现一名患者在股骨部件周围有进展的放射透光线,一名患者有髋臼囊肿,以及一名患者有松动的锁环(但没有失败)。本次随访的19例患者Harris髋关节评分平均为81分。约束线性是处理固定良好的构件反复位错的有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信