{"title":"The effects of earphones and music on the temperature measured by infrared tympanic thermmeter: preliminary results.","authors":"Alvisa Palese,&nbsp;Davide Pasqualini","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The main aim of the study was to evaluate the effect on subjects' temperature measurement readings when using the infrared tympanic thermometer after correct earphone placement and use, with or without music transmission through the earphone.</p><p><strong>Methods: </strong>A comparative study design was adopted. A sample of 39 healthy people was randomly divided into three groups. Subjects in all groups used an earphone that had been correctly placed in the right ear only: Group 1: listened to heavy metal music through the earphone (13 participants); Group 2: listened to classical music through the earphone (13 participants); Group 3: no music or sound was transmitted through the earphone (13 participants). Average differences (CI 95%) and Pearson correlations for the temperature measured in the right ear, which was exposed to the different independent variables, and the left ear which was not exposed, were calculated at different times: (1) after 10 minutes compared to the baseline measurement; (2) after 30 minutes compared to the 10 minutes measurement; and (3) after 30 minutes compared to the baseline measurement.</p><p><strong>Results: </strong>The inter-ear temperature correlation at the baseline was Pearson r .801 (p = .01). There was a significant decrease in the correlations between right and left ear temperatures in Group 1 and in Group 3 which was demonstrated after 10 minutes of earphone use, and reached critical values after 30 minutes of use in all groups. The average warmth in the right ear, as perceived by participants after 20 minutes, was reported. Using the Numerical Rating Score the average was 3.3 +/- 1.3 for Group 1, for Group 2 was 1.9 +/- 1.3 and for Group 3 was 3.3 +/- 1.2 (p = .05).</p><p><strong>Conclusion: </strong>Within the limitations of the study, which involved a limited number of healthy people the results show that it is best to not measure tympanic temperature in an ear that has very recently had an earphone in place.</p>","PeriodicalId":79417,"journal":{"name":"ORL-head and neck nursing : official journal of the Society of Otorhinolaryngology and Head-Neck Nurses","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ORL-head and neck nursing : official journal of the Society of Otorhinolaryngology and Head-Neck Nurses","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The main aim of the study was to evaluate the effect on subjects' temperature measurement readings when using the infrared tympanic thermometer after correct earphone placement and use, with or without music transmission through the earphone.

Methods: A comparative study design was adopted. A sample of 39 healthy people was randomly divided into three groups. Subjects in all groups used an earphone that had been correctly placed in the right ear only: Group 1: listened to heavy metal music through the earphone (13 participants); Group 2: listened to classical music through the earphone (13 participants); Group 3: no music or sound was transmitted through the earphone (13 participants). Average differences (CI 95%) and Pearson correlations for the temperature measured in the right ear, which was exposed to the different independent variables, and the left ear which was not exposed, were calculated at different times: (1) after 10 minutes compared to the baseline measurement; (2) after 30 minutes compared to the 10 minutes measurement; and (3) after 30 minutes compared to the baseline measurement.

Results: The inter-ear temperature correlation at the baseline was Pearson r .801 (p = .01). There was a significant decrease in the correlations between right and left ear temperatures in Group 1 and in Group 3 which was demonstrated after 10 minutes of earphone use, and reached critical values after 30 minutes of use in all groups. The average warmth in the right ear, as perceived by participants after 20 minutes, was reported. Using the Numerical Rating Score the average was 3.3 +/- 1.3 for Group 1, for Group 2 was 1.9 +/- 1.3 and for Group 3 was 3.3 +/- 1.2 (p = .05).

Conclusion: Within the limitations of the study, which involved a limited number of healthy people the results show that it is best to not measure tympanic temperature in an ear that has very recently had an earphone in place.

耳机和音乐对红外线鼓室温度计测温的影响:初步结果。
目的:本研究的主要目的是评估在正确放置和使用耳机后,使用红外线鼓膜体温计时,通过耳机传输或不通过耳机传输音乐对受试者体温测量读数的影响。方法:采用比较研究设计。39名健康的人被随机分为三组。所有组的受试者只使用正确放置在右耳中的耳机:第一组:通过耳机听重金属音乐(13名参与者);第二组:通过耳机听古典音乐(13人);第三组:没有音乐或声音通过耳机传输(13名参与者)。计算暴露于不同自变量的右耳和未暴露于不同自变量的左耳测得的温度在不同时间的平均差异(CI 95%)和Pearson相关性:(1)与基线测量相比,10分钟后;(2) 30分钟后与10分钟测量时的对比;(3) 30分钟后与基线测量值比较。结果:基线时耳际温度相关性Pearson r = 0.801 (p = 0.01)。第1组和第3组右耳和左耳温度的相关性在使用耳机10分钟后显著下降,在使用耳机30分钟后均达到临界值。报告了参与者在20分钟后感受到的平均右耳温度。使用数值评定评分,组1的平均值为3.3 +/- 1.3,组2的平均值为1.9 +/- 1.3,组3的平均值为3.3 +/- 1.2 (p = 0.05)。结论:在这项研究的范围内,它只涉及了有限数量的健康人群,结果表明,最好不要在最近戴过耳机的耳朵里测量鼓室温度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信