Magnitude and Implications of Interfraction Variations in Organ Doses during High Dose Rate Brachytherapy of Cervix Cancer: A CT Based Planning Study.

ISRN oncology Pub Date : 2014-02-03 eCollection Date: 2014-01-01 DOI:10.1155/2014/687365
Santam Chakraborty, Firuza D Patel, Vijay M Patil, Arun S Oinam, Suresh C Sharma
{"title":"Magnitude and Implications of Interfraction Variations in Organ Doses during High Dose Rate Brachytherapy of Cervix Cancer: A CT Based Planning Study.","authors":"Santam Chakraborty,&nbsp;Firuza D Patel,&nbsp;Vijay M Patil,&nbsp;Arun S Oinam,&nbsp;Suresh C Sharma","doi":"10.1155/2014/687365","DOIUrl":null,"url":null,"abstract":"<p><p>Background. Quantifying the interfraction dose variations in the organs at risk (OAR) in HDR intracavitary brachytherapy (HDR ICBT). Methods. Rectum and bladder were contoured in 44 patients of cervical carcinoma on CT after each fraction of HDR ICBT (9 Gy/2 fractions). Interfraction dose variations (VARact) were calculated. Rigid image registration of consecutive fraction images allowed quantification of the hypothetical variation in dose (VARhypo) arising exclusively due to changes in applicator placement and geometry. VARhypo was regressed against the VARact to find out to what extent the applicator variation could explain the VARact in the OAR. The rest of the variation was assumed to be due to organ deformation. Results. The VARact in the dose to 2 cc of bladder and rectum were 1.46 and 1.16 Gy, respectively. Increased dose was seen in 16 and 23 patients in the subsequent fraction for bladder and rectum, respectively. Doses to OAR would have exceeded constraints in 16% patients if second fraction was not imaged. VARhypo explained 19% and 47% of the VARact observed for the bladder and rectum respectively. Conclusions. Significant interfraction variations in OAR doses can occur in HDR ICBT. Organ deformations are mostly responsible for this variation. </p>","PeriodicalId":89399,"journal":{"name":"ISRN oncology","volume":"2014 ","pages":"687365"},"PeriodicalIF":0.0000,"publicationDate":"2014-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2014/687365","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2014/687365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

Background. Quantifying the interfraction dose variations in the organs at risk (OAR) in HDR intracavitary brachytherapy (HDR ICBT). Methods. Rectum and bladder were contoured in 44 patients of cervical carcinoma on CT after each fraction of HDR ICBT (9 Gy/2 fractions). Interfraction dose variations (VARact) were calculated. Rigid image registration of consecutive fraction images allowed quantification of the hypothetical variation in dose (VARhypo) arising exclusively due to changes in applicator placement and geometry. VARhypo was regressed against the VARact to find out to what extent the applicator variation could explain the VARact in the OAR. The rest of the variation was assumed to be due to organ deformation. Results. The VARact in the dose to 2 cc of bladder and rectum were 1.46 and 1.16 Gy, respectively. Increased dose was seen in 16 and 23 patients in the subsequent fraction for bladder and rectum, respectively. Doses to OAR would have exceeded constraints in 16% patients if second fraction was not imaged. VARhypo explained 19% and 47% of the VARact observed for the bladder and rectum respectively. Conclusions. Significant interfraction variations in OAR doses can occur in HDR ICBT. Organ deformations are mostly responsible for this variation.

Abstract Image

Abstract Image

Abstract Image

宫颈癌高剂量率近距离放疗期间器官剂量干扰变化的幅度和意义:一项基于CT的计划研究。
背景。定量HDR腔内近距离放射治疗(HDR ICBT)中危险器官(OAR)的相互作用剂量变化。方法。对44例宫颈癌患者进行HDR ICBT (9 Gy/2次)后的直肠和膀胱的CT轮廓。计算干涉剂量变化(VARact)。连续分数图像的严格图像配准允许定量假设剂量变化(VARhypo),这完全是由于涂抹器放置和几何形状的变化而引起的。将VARhypo与VARact进行回归,以找出涂抹器变异在多大程度上可以解释OAR中的VARact。其余的变异被认为是由于器官变形。结果。膀胱和直肠2cc剂量的VARact分别为1.46和1.16 Gy。在膀胱和直肠的后续部分中,分别有16例和23例患者的剂量增加。如果第二部分没有成像,16%的患者对OAR的剂量将超过限制。VARhypo分别解释了膀胱和直肠VARact的19%和47%。结论。在HDR ICBT中,可发生OAR剂量的显著干涉变化。器官变形是造成这种变异的主要原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信