Noninvasive electromagnetic detection of bladder cancer.

ISRN urology Pub Date : 2014-01-16 eCollection Date: 2014-01-01 DOI:10.1155/2014/802328
Luigi Cormio, Clarbruno Vedruccio, Giorgio Leucci, Paolo Massenio, Giuseppe Di Fino, Vincenzo Cavaliere, Giuseppe Carrieri
{"title":"Noninvasive electromagnetic detection of bladder cancer.","authors":"Luigi Cormio,&nbsp;Clarbruno Vedruccio,&nbsp;Giorgio Leucci,&nbsp;Paolo Massenio,&nbsp;Giuseppe Di Fino,&nbsp;Vincenzo Cavaliere,&nbsp;Giuseppe Carrieri","doi":"10.1155/2014/802328","DOIUrl":null,"url":null,"abstract":"<p><p>Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC. </p>","PeriodicalId":89401,"journal":{"name":"ISRN urology","volume":"2014 ","pages":"802328"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2014/802328","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN urology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2014/802328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC.

Abstract Image

膀胱癌的无创电磁检测。
目标。正常和肿瘤人体组织具有不同的电磁特性。本研究旨在探讨组织共振相互作用法(TRIM-prob)对膀胱癌(BC)无创电磁检测的诊断准确性。患者和方法。由于(i)显微镜或肉眼血尿和/或刺激性排尿症状和(ii)膀胱超声和尿细胞学检查结果阴性或仅怀疑恶性肿瘤,连续患者被转介进行膀胱镜检查。患者首先由一名研究者进行trim - probb膀胱扫描,然后由另一名研究者进行膀胱镜检查,对trim - probb数据不知情。结果。125例患者膀胱镜检查BC阳性47例,阴性78例;相反,trim - probb膀胱扫描BC阳性53例,阴性72例。特别是,trim - probb扫描产生7个假阳性,只有1个假阴性;因此,其总体敏感性、特异性、阳性预测值、阴性预测值、诊断准确率分别为97.9%、89.9%、86.8%、98.6%、93.6%。结论。trim - probb膀胱扫描是一种简便、准确的无创BC电磁检测方法。如果升高的阳性和阴性预测值将在进一步精心设计的研究中得到重复,则可用于筛查无症状的高风险BC患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书