Provider Adherence to Neonatal Resuscitation Program Recommendations for Coordinated Neonatal Chest Compressions and Ventilations.

Elizabeth Foglia, Jay Patel, Dana Niles, Per Helge Aasland, Vinay Nadkarni, Anne Ades
{"title":"Provider Adherence to Neonatal Resuscitation Program Recommendations for Coordinated Neonatal Chest Compressions and Ventilations.","authors":"Elizabeth Foglia,&nbsp;Jay Patel,&nbsp;Dana Niles,&nbsp;Per Helge Aasland,&nbsp;Vinay Nadkarni,&nbsp;Anne Ades","doi":"10.4172/2324-903X.S1-010","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Medical providers often do not perform chest compressions in accordance with recommended resuscitation guidelines for adults and children. Little is known regarding how well neonatal providers perform coordinated chest compressions and ventilations. The objective of this study was to characterize Neonatal Resuscitation Program (NRP) trained providers' adherence to NRP recommendations for coordinated chest compressions and ventilations in a simulated setting.</p><p><strong>Methods: </strong>Fifty NRP providers performed coordinated chest compressions for three minutes on a neonatal manikin. A compression sensor (accelerometer) was used to monitor and record compression data. Data analyzed included ratio of compressions to ventilation pauses, delivered chest compressions per minute (CC/min), and duration of ventilation pauses.</p><p><strong>Results: </strong>Delivered CC/min ranged from 61 to 136. The mean CC/min (99, SD 16) was significantly higher than the NRP-recommended value of 90 (p=0.002). Delivered CC/min did not differ from the first 30 seconds to the last 30 seconds of compressions (p=0.91). Duration of ventilation pauses was highly correlated with CC/min (Spearman's rho= -0.98, p<0.001), with a median duration of 0.92 seconds (IQ range (0.84, 1.02).</p><p><strong>Conclusions: </strong>NRP trained providers often do not adhere to NRP recommendations for delivery of coordinated chest compressions during simulated cardiac depression. The mean CC/min performed is higher than recommended. Duration of ventilation pauses is highly correlated with delivered CC/min. Future studies should focus on methods to improve the timing of delivered chest compressions by NRP providers to conform to NRP recommendations.</p>","PeriodicalId":89888,"journal":{"name":"Analgesia & resuscitation : current research","volume":"Suppl 1 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2013-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3817008/pdf/nihms510023.pdf","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analgesia & resuscitation : current research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2324-903X.S1-010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Aim: Medical providers often do not perform chest compressions in accordance with recommended resuscitation guidelines for adults and children. Little is known regarding how well neonatal providers perform coordinated chest compressions and ventilations. The objective of this study was to characterize Neonatal Resuscitation Program (NRP) trained providers' adherence to NRP recommendations for coordinated chest compressions and ventilations in a simulated setting.

Methods: Fifty NRP providers performed coordinated chest compressions for three minutes on a neonatal manikin. A compression sensor (accelerometer) was used to monitor and record compression data. Data analyzed included ratio of compressions to ventilation pauses, delivered chest compressions per minute (CC/min), and duration of ventilation pauses.

Results: Delivered CC/min ranged from 61 to 136. The mean CC/min (99, SD 16) was significantly higher than the NRP-recommended value of 90 (p=0.002). Delivered CC/min did not differ from the first 30 seconds to the last 30 seconds of compressions (p=0.91). Duration of ventilation pauses was highly correlated with CC/min (Spearman's rho= -0.98, p<0.001), with a median duration of 0.92 seconds (IQ range (0.84, 1.02).

Conclusions: NRP trained providers often do not adhere to NRP recommendations for delivery of coordinated chest compressions during simulated cardiac depression. The mean CC/min performed is higher than recommended. Duration of ventilation pauses is highly correlated with delivered CC/min. Future studies should focus on methods to improve the timing of delivered chest compressions by NRP providers to conform to NRP recommendations.

提供者坚持新生儿复苏计划建议协调新生儿胸外按压和通气。
目的:医疗提供者通常不按照成人和儿童复苏指南的建议进行胸外按压。关于新生儿提供者如何很好地进行协调的胸部按压和通气,人们知之甚少。本研究的目的是描述新生儿复苏计划(NRP)培训提供者在模拟环境中遵守NRP建议协调胸外按压和通气的情况。方法:50名NRP提供者对新生儿假人进行协调的胸部按压3分钟。压缩传感器(加速度计)用于监测和记录压缩数据。分析的数据包括按压与通气暂停的比率、每分钟胸腔按压次数(CC/min)和通气暂停的持续时间。结果:CC/min范围为61 ~ 136。平均CC/min (99, SD 16)显著高于nrp推荐值90 (p=0.002)。按压前30秒与按压后30秒的CC/min无显著差异(p=0.91)。通气暂停时间与CC/min高度相关(Spearman’s rho= -0.98)。结论:经过NRP培训的医护人员通常不遵守NRP的建议,在模拟心脏抑制期间进行协调的胸外按压。执行的平均CC/min高于推荐值。通气暂停时间与输送的CC/min高度相关。未来的研究应侧重于改进NRP提供者进行胸外按压的时机,以符合NRP的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书