Catheter Ablation of Atrial Flutter in Patients With Left Ventricular Assist Device Improves Symptoms of Right Heart Failure

Rashmi U. Hottigoudar MD, Allen G. Deam MD, Emma J. Birks MD, PhD, Kelly C. McCants MD, Mark S. Slaughter MD, Rakesh Gopinathannair MD, MA
{"title":"Catheter Ablation of Atrial Flutter in Patients With Left Ventricular Assist Device Improves Symptoms of Right Heart Failure","authors":"Rashmi U. Hottigoudar MD,&nbsp;Allen G. Deam MD,&nbsp;Emma J. Birks MD, PhD,&nbsp;Kelly C. McCants MD,&nbsp;Mark S. Slaughter MD,&nbsp;Rakesh Gopinathannair MD, MA","doi":"10.1111/chf.12034","DOIUrl":null,"url":null,"abstract":"<div>\n <p>Persistent atrial flutter (AFL) in left ventricular assist device (LVAD) recipients can result in loss of AV synchrony, impaired ventricular filling and right heart failure (RHF). The authors report the largest series of HeartMate II (HMII) patients who developed AFL with decompensated RHF, which successfully resolved with AFL ablation. Eight patients with HMII LVAD (mean age, 57±12 years) had medically refractory AFL, with 7 developing de novo AFL after LVAD implant (onset range, 2 days–22 months post-implant). Three patients developed recurrent syncope, 2 had inappropriate implantable cardioverter-defibrillator shocks, and 6 had new or escalating need for inotropes. All had features of decompensated RHF. Seven patients underwent electrophysiology testing where mapping confirmed typical counterclockwise AFL (mean AFL cycle length, 252±49 ms) and radiofrequency ablation of cavotricuspid isthmus restored sinus rhythm in all patients. Complete resolution of symptoms and signs of RHF with improved quality of life were noted in all. No procedural complications were noted. During a mean follow-up of 9±5 months, all patients remained free of atrial flutter. Catheter ablation of AFL in LVAD patients is safe and highly effective, resulting in immediate and significant improvement in symptoms of RHF, and should be considered first-line therapy for AFL in these patients.</p>\n </div>","PeriodicalId":83668,"journal":{"name":"Congestive heart failure (Greenwich, Conn.)","volume":"19 4","pages":"165-171"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/chf.12034","citationCount":"31","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Congestive heart failure (Greenwich, Conn.)","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/chf.12034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

Abstract

Persistent atrial flutter (AFL) in left ventricular assist device (LVAD) recipients can result in loss of AV synchrony, impaired ventricular filling and right heart failure (RHF). The authors report the largest series of HeartMate II (HMII) patients who developed AFL with decompensated RHF, which successfully resolved with AFL ablation. Eight patients with HMII LVAD (mean age, 57±12 years) had medically refractory AFL, with 7 developing de novo AFL after LVAD implant (onset range, 2 days–22 months post-implant). Three patients developed recurrent syncope, 2 had inappropriate implantable cardioverter-defibrillator shocks, and 6 had new or escalating need for inotropes. All had features of decompensated RHF. Seven patients underwent electrophysiology testing where mapping confirmed typical counterclockwise AFL (mean AFL cycle length, 252±49 ms) and radiofrequency ablation of cavotricuspid isthmus restored sinus rhythm in all patients. Complete resolution of symptoms and signs of RHF with improved quality of life were noted in all. No procedural complications were noted. During a mean follow-up of 9±5 months, all patients remained free of atrial flutter. Catheter ablation of AFL in LVAD patients is safe and highly effective, resulting in immediate and significant improvement in symptoms of RHF, and should be considered first-line therapy for AFL in these patients.

Abstract Image

采用左心室辅助装置的患者心房扑动导管消融可改善右心衰症状
左心室辅助装置(LVAD)接受者持续心房扑动(AFL)可导致房室同步性丧失、心室充盈受损和右心衰(RHF)。作者报告了发生AFL并伴有失代偿性RHF的最大系列HeartMate II (HMII)患者,这些患者通过AFL消融成功解决。8例HMII LVAD患者(平均年龄57±12岁)出现难治性AFL,其中7例在LVAD植入后发生新发AFL(发病时间范围为植入后2天- 22个月)。3名患者出现复发性晕厥,2名患者有不适当的植入式心律转复除颤器电击,6名患者有新的或不断增加的肌力药物需求。所有患者均具有失代偿性RHF特征。7例患者接受了电生理测试,测图证实了典型的逆时针AFL(平均AFL周期长度,252±49 ms),所有患者的腔尖瓣峡部射频消融恢复了窦性心律。所有患者均注意到RHF症状和体征完全消退,生活质量得到改善。未见手术并发症。在平均9±5个月的随访中,所有患者均无心房扑动。对于LVAD患者,导管消融AFL安全、高效,可立即显著改善RHF症状,应考虑作为此类患者AFL的一线治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书