Identification of the First Japanese Family Harboring a Novel Hemoglobin Variant "Perpignan", Which Caused Low HbA1c Measurement During Diabetic Follow-Up.
{"title":"Identification of the First Japanese Family Harboring a Novel Hemoglobin Variant \"Perpignan\", Which Caused Low HbA1c Measurement During Diabetic Follow-Up.","authors":"Mami Nakamura, Ayako Miyazaki, Takayuki Takubo, Yoko Matsuzawa, Jun Saito, Masao Omura, Tetsuo Nishikawa","doi":"10.4137/JCM.S5971","DOIUrl":null,"url":null,"abstract":"Hemoglobin A1c (HbA1c) is an important parameter for evaluating long-term (6–8 weeks) control of blood glucose levels in patients with diabetes mellitus. We report a Japanese diabetic case who harbored abnormal Hb and demonstrated falsely low HbA1c levels in the regular ion exchange HPLC-based assay. His abnormal β-globin chain had an amino acid replacement that corresponded to glycine to serine substitution at amino acid position 136 of the β-globin chain (Hb Perpignan). Accordingly, a heterozygotic point mutation replacing guanine by adenine at nucleotide position 406 (β136G > S) was identified in the β-globin gene of the proband and his son. These results indicate that the patient had Hb Perpignan, and this abnormal Hb interfered with the HPLC-based HbA1c assay commonly used in the clinic. The cases presented are the first report of patients in the Japanese population harboring Hb Perpignan (β136G > S).","PeriodicalId":89792,"journal":{"name":"Japanese clinical medicine","volume":"2 ","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2011-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/JCM.S5971","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese clinical medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/JCM.S5971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/1/1 0:00:00","PubModel":"Print","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Hemoglobin A1c (HbA1c) is an important parameter for evaluating long-term (6–8 weeks) control of blood glucose levels in patients with diabetes mellitus. We report a Japanese diabetic case who harbored abnormal Hb and demonstrated falsely low HbA1c levels in the regular ion exchange HPLC-based assay. His abnormal β-globin chain had an amino acid replacement that corresponded to glycine to serine substitution at amino acid position 136 of the β-globin chain (Hb Perpignan). Accordingly, a heterozygotic point mutation replacing guanine by adenine at nucleotide position 406 (β136G > S) was identified in the β-globin gene of the proband and his son. These results indicate that the patient had Hb Perpignan, and this abnormal Hb interfered with the HPLC-based HbA1c assay commonly used in the clinic. The cases presented are the first report of patients in the Japanese population harboring Hb Perpignan (β136G > S).