W D Nafarnda, I E Ajayi, J C Shawulu, M S Kawe, G K Omeiza, N A Sani, O Z Tenuche, D D Dantong, S Z Tags
{"title":"Bacteriological quality of abattoir effluents discharged into water bodies in abuja, Nigeria.","authors":"W D Nafarnda, I E Ajayi, J C Shawulu, M S Kawe, G K Omeiza, N A Sani, O Z Tenuche, D D Dantong, S Z Tags","doi":"10.5402/2012/515689","DOIUrl":null,"url":null,"abstract":"<p><p>Bacteriological characteristics of abattoir effluents (wastewater), abattoir water source, and water bodies receiving abattoir wastewater were investigated in Abuja, Nigeria using the multiple-tube fermentation technique. Source of water to the abattoirs and the usage of water bodies receiving abattoir effluents were determined using questionnaires. Bacterial counts ranged from 4.8 × 10(6) to 5.8 × 10(5) /100 mL of total coliform (TC), 8.2 × 10(4) to 3.2 × 10(4)/100 mL of Fecal coliform (FC), 5.2 × 10(4) to 2.0 × 10(4)/100 mL of Fecal streptococcus and 1.2 × 10(4) to 2.0 × 10(3)/100 mL of Escherichia coli for abattoir effluents 6.6 × 10(5) to 6.0 × 10(5)/100 mL of TC, 6.2 × 10(4) to 1.8 × 10(4)/100 mL of FC, 1.8 × 10(4) to 6.0 × 10(3)/100 mL of F. streptococcus, and 4.8 × 10(3) to 6.6 × 10(2)/100 mL of E. coli for water bodies receiving abattoir effluents 100 m downstream. TC bacteria counts for abattoir effluents exceeded recommended limit for discharge into surface water in Nigeria. No significant difference (P < 0.05) was observed between bacterial counts of abattoir effluents and receiving water bodies 100 m downstream: an indication of contamination of receiving water bodies by abattoir effluents and possible public and environmental health hazards.</p>","PeriodicalId":89682,"journal":{"name":"ISRN veterinary science","volume":"2012 ","pages":"515689"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5402/2012/515689","citationCount":"64","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN veterinary science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2012/515689","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/1/1 0:00:00","PubModel":"Print","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 64
Abstract
Bacteriological characteristics of abattoir effluents (wastewater), abattoir water source, and water bodies receiving abattoir wastewater were investigated in Abuja, Nigeria using the multiple-tube fermentation technique. Source of water to the abattoirs and the usage of water bodies receiving abattoir effluents were determined using questionnaires. Bacterial counts ranged from 4.8 × 10(6) to 5.8 × 10(5) /100 mL of total coliform (TC), 8.2 × 10(4) to 3.2 × 10(4)/100 mL of Fecal coliform (FC), 5.2 × 10(4) to 2.0 × 10(4)/100 mL of Fecal streptococcus and 1.2 × 10(4) to 2.0 × 10(3)/100 mL of Escherichia coli for abattoir effluents 6.6 × 10(5) to 6.0 × 10(5)/100 mL of TC, 6.2 × 10(4) to 1.8 × 10(4)/100 mL of FC, 1.8 × 10(4) to 6.0 × 10(3)/100 mL of F. streptococcus, and 4.8 × 10(3) to 6.6 × 10(2)/100 mL of E. coli for water bodies receiving abattoir effluents 100 m downstream. TC bacteria counts for abattoir effluents exceeded recommended limit for discharge into surface water in Nigeria. No significant difference (P < 0.05) was observed between bacterial counts of abattoir effluents and receiving water bodies 100 m downstream: an indication of contamination of receiving water bodies by abattoir effluents and possible public and environmental health hazards.