Sampling, extraction and measurement of bacteria, endotoxin, fungi and inflammatory potential of settling indoor dust.

Journal of Environmental Monitoring Pub Date : 2012-12-01 Epub Date: 2012-11-15 DOI:10.1039/c2em30699a
Anne Mette Madsen, Christoffer B Matthiesen, Margit W Frederiksen, Marie Frederiksen, Mika Frankel, Michal Spilak, Lars Gunnarsen, Michael Timm
{"title":"Sampling, extraction and measurement of bacteria, endotoxin, fungi and inflammatory potential of settling indoor dust.","authors":"Anne Mette Madsen,&nbsp;Christoffer B Matthiesen,&nbsp;Margit W Frederiksen,&nbsp;Marie Frederiksen,&nbsp;Mika Frankel,&nbsp;Michal Spilak,&nbsp;Lars Gunnarsen,&nbsp;Michael Timm","doi":"10.1039/c2em30699a","DOIUrl":null,"url":null,"abstract":"<p><p>Selection of sampling device, sampling location and period are important first steps in the measurement of exposure to bioaerosols in indoor air. The steps following the sampling include treatment of samples and laboratory analysis. In this study, settling bacteria, endotoxin, fungi and serine protease have been measured in Danish homes using Electrostatic Dust Fall Collectors (EDCs). The effects of the presence of occupants, sampling on open surfaces versus in bookcases and treatment of samples have been studied. Concentrations of bacteria and endotoxin were significantly higher when occupants were at home than when they were absent. Across homes, higher concentrations of fungi were found in spring than in winter, as was the total inflammatory potential, while higher concentrations of protease were found in winter than in spring. The placement of the EDCs in bookcases versus on an open surface significantly affected the measured concentrations of bacteria and endotoxin. Direct extraction of EDC cloths caused a higher measured concentration of bacteria, fungi and serine protease than if EDC cloths were extracted post-storage at -20 °C. Extraction of EDC cloths caused an average of 51% and 58% extraction of bacteria and fungi respectively. In conclusion, EDCs should be placed on open surfaces during the sampling, how much occupants are present in their home during sampling and sampling season should be considered, EDC cloths should not be stored in a freezer before extraction of microorganisms, but extraction suspensions can be stored at -80 °C without affecting the number of microorganisms significantly.</p>","PeriodicalId":50202,"journal":{"name":"Journal of Environmental Monitoring","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1039/c2em30699a","citationCount":"70","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Monitoring","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1039/c2em30699a","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/11/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 70

Abstract

Selection of sampling device, sampling location and period are important first steps in the measurement of exposure to bioaerosols in indoor air. The steps following the sampling include treatment of samples and laboratory analysis. In this study, settling bacteria, endotoxin, fungi and serine protease have been measured in Danish homes using Electrostatic Dust Fall Collectors (EDCs). The effects of the presence of occupants, sampling on open surfaces versus in bookcases and treatment of samples have been studied. Concentrations of bacteria and endotoxin were significantly higher when occupants were at home than when they were absent. Across homes, higher concentrations of fungi were found in spring than in winter, as was the total inflammatory potential, while higher concentrations of protease were found in winter than in spring. The placement of the EDCs in bookcases versus on an open surface significantly affected the measured concentrations of bacteria and endotoxin. Direct extraction of EDC cloths caused a higher measured concentration of bacteria, fungi and serine protease than if EDC cloths were extracted post-storage at -20 °C. Extraction of EDC cloths caused an average of 51% and 58% extraction of bacteria and fungi respectively. In conclusion, EDCs should be placed on open surfaces during the sampling, how much occupants are present in their home during sampling and sampling season should be considered, EDC cloths should not be stored in a freezer before extraction of microorganisms, but extraction suspensions can be stored at -80 °C without affecting the number of microorganisms significantly.

室内尘埃的细菌、内毒素、真菌和炎症潜势的取样、提取和测定。
采样装置的选择、采样地点和采样周期是测量室内空气中生物气溶胶暴露的重要步骤。取样后的步骤包括样品处理和实验室分析。在这项研究中,使用静电除尘器(EDCs)测量了丹麦家庭中的沉降细菌、内毒素、真菌和丝氨酸蛋白酶。已经研究了居住者存在的影响,在开放表面上取样与在书架上取样以及样品的处理。当居住者在家时,细菌和内毒素的浓度明显高于他们不在家时。在所有家庭中,春季真菌浓度高于冬季,总炎症潜力也高于冬季,而冬季蛋白酶浓度高于春季。EDCs放置在书架上与放置在开放表面上显著影响细菌和内毒素的测量浓度。直接提取EDC布的细菌、真菌和丝氨酸蛋白酶的测量浓度高于在-20°C保存后提取EDC布。EDC布的平均细菌提取率为51%,真菌提取率为58%。综上所述,取样时应将EDC放置在开放的表面上,取样期间和采样季节应考虑家中有多少人,在提取微生物之前不应将EDC布存放在冰箱中,但提取悬浮液可以在-80°C下保存,而不会显著影响微生物的数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Environmental Monitoring
Journal of Environmental Monitoring 环境科学-分析化学
自引率
0.00%
发文量
0
审稿时长
2.3 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信