{"title":"LC-MS/MS method for determination of epothilone B in rat plasma and its application in pharmacokinetic study.","authors":"H-M Lu, M Ye","doi":"10.1055/s-0032-1327695","DOIUrl":null,"url":null,"abstract":"<p><p>A simple LC-MS/MS method was developed for determination and pharmacokinetic study of Epothilone B in rat plasma.Plasma sample pretreatment involved a one-step liquid-liquid extraction of 100 µL plasma. The chromatographic separation was carried out on a Agilent Zobax SB C18 column with a mobile phase consisting of 10 mmol/L ammonium acetate-acetonitrile (35:65, v/v) at a flow rate of 0.2 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by SRM via electro spray ionization source with positive mode.The standard curve for Epothilone B was linear over the concentration range of 1-100 ng/mL with a lower limit of quantification of 0.5 ng/mL. The intra- and inter-day precision (relative standard deviation) values were not higher than 15% and the accuracy (relative error) was < 10% at 3 quality control levels. Pharmacokinetic parameters were as follows: t1/2, 3.56 (1.12) h; AUC0-24 h, 295.7 (65.3) ng · h/mL and AUC0-∞, 339.2 (87.4) ng · h/mL, CL, 5.77 (0.67) mL/h; MRT, 7.55 (2.41) h, respectively.This simple, fast and highly sensitive method was fully validated and successfully applied to a preclinical pharmacokinetic study of Epothilone B in rats after i. v. administration.</p>","PeriodicalId":56084,"journal":{"name":"Arzneimittel-Forschung-Drug Research","volume":"62 12","pages":"609-13"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0032-1327695","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arzneimittel-Forschung-Drug Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0032-1327695","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/10/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
A simple LC-MS/MS method was developed for determination and pharmacokinetic study of Epothilone B in rat plasma.Plasma sample pretreatment involved a one-step liquid-liquid extraction of 100 µL plasma. The chromatographic separation was carried out on a Agilent Zobax SB C18 column with a mobile phase consisting of 10 mmol/L ammonium acetate-acetonitrile (35:65, v/v) at a flow rate of 0.2 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by SRM via electro spray ionization source with positive mode.The standard curve for Epothilone B was linear over the concentration range of 1-100 ng/mL with a lower limit of quantification of 0.5 ng/mL. The intra- and inter-day precision (relative standard deviation) values were not higher than 15% and the accuracy (relative error) was < 10% at 3 quality control levels. Pharmacokinetic parameters were as follows: t1/2, 3.56 (1.12) h; AUC0-24 h, 295.7 (65.3) ng · h/mL and AUC0-∞, 339.2 (87.4) ng · h/mL, CL, 5.77 (0.67) mL/h; MRT, 7.55 (2.41) h, respectively.This simple, fast and highly sensitive method was fully validated and successfully applied to a preclinical pharmacokinetic study of Epothilone B in rats after i. v. administration.