Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study.

ISRN dentistry Pub Date : 2012-01-01 Epub Date: 2012-07-18 DOI:10.5402/2012/328945
Mansour Rismanchian, Bijan Movahedian, Navid Khalighinejad, Hamid Badrian, Sayed Mohammad Razavi, Afsaneh Nekouie
{"title":"Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study.","authors":"Mansour Rismanchian,&nbsp;Bijan Movahedian,&nbsp;Navid Khalighinejad,&nbsp;Hamid Badrian,&nbsp;Sayed Mohammad Razavi,&nbsp;Afsaneh Nekouie","doi":"10.5402/2012/328945","DOIUrl":null,"url":null,"abstract":"<p><p>Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (α = 0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P = 0.004). None of the histomorphometric values showed significant differences between the two implants (P > 0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact.</p>","PeriodicalId":89396,"journal":{"name":"ISRN dentistry","volume":"2012 ","pages":"328945"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3407639/pdf/","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2012/328945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/7/18 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (α = 0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P = 0.004). None of the histomorphometric values showed significant differences between the two implants (P > 0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact.

Abstract Image

Abstract Image

使用生物力学和组织形态计量学测试对两种类型即刻加载植入物的比较评估:动物案例研究。
介绍。为了尽量减少恢复美观和功能所需的时间,建议立即加载植入物。本研究的目的是通过生物力学和组织形态学测试对Nisastan和XIve植入物进行比较评价。材料与方法。本实验选用Nisastan一体式即刻加载螺钉型种植体(OPILS) 6个,Xive种植体6个,直径3.4 mm,长11 mm。植入物立即被装入临时涂层。三个月后,测量并记录骨折与植入物接触所需的扭矩。所有种植体与周围骨一起取出并进行组织学评估。数据输入SPSS 11.5软件进行学生t检验统计分析(α = 0.05)。结果。两种种植体的成功率均为100%,均未因活动或骨质流失而失败。Xive和Nisastan种植体的平均去除扭矩值(RTV)分别为142.08和40 N/Cm,两种种植体的RTV差异有统计学意义(P = 0.004)。两种种植体的组织形态测量值差异无统计学意义(P > 0.05)。讨论。这两种系统都有能力在直接载荷下诱导骨整合,但Xive种植体显示出更高的骨接触能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信