Hemodynamic, Echocardiographic, and Exercise-Related Effects of the HeartWare Left Ventricular Assist Device in Advanced Heart Failure

Adam McDiarmid MB, Brian Gordon PhD, Neil Wrightson BSc, Nicola Robinson-Smith BA, Thasee Pillay FRCS (CTh), Gareth Parry FRCP, Stephan Schueler MD, Guy A. MacGowan MD
{"title":"Hemodynamic, Echocardiographic, and Exercise-Related Effects of the HeartWare Left Ventricular Assist Device in Advanced Heart Failure","authors":"Adam McDiarmid MB,&nbsp;Brian Gordon PhD,&nbsp;Neil Wrightson BSc,&nbsp;Nicola Robinson-Smith BA,&nbsp;Thasee Pillay FRCS (CTh),&nbsp;Gareth Parry FRCP,&nbsp;Stephan Schueler MD,&nbsp;Guy A. MacGowan MD","doi":"10.1111/j.1751-7133.2012.00302.x","DOIUrl":null,"url":null,"abstract":"<p>©2012 Wiley Periodicals, Inc.</p><p>The aim of this study was to determine the effects of the HeartWare left ventricular assist device (HVAD) (HeartWare International, Inc, Framingham, MA) on hemodynamics, ventricular function, and exercise capacity. Between July 2009 and March 2011, 46 patients with advanced heart failure had implantation of the HVAD. Of these patients, 30 had subsequent assessments for transplantation and these patients formed the study cohort. Thirty patients had assessments at a mean of 201±86 days and 13 went on to have a second assessment at 351±86 days. There were marked improvements in hemodynamics and exercise capacity at both assessments, with significant decreases in right and left heart filling pressures; increases in cardiac index, New York Heart Association class, and peak exercise oxygen consumption; and reduction in pulmonary vascular resistance (all <i>P</i>&lt;.05). Left ventricular end-diastolic and end-systolic dimensions were unchanged at the first assessment, although there was a significant reduction in end-diastolic diameter at the second assessment (<i>P</i>&lt;.01). There were no significant changes in a visual grade of right ventricular function. After up to 1 year of support, the HVAD system results in significant benefits in overall heart failure status, with improved hemodynamics and exercise capacity. This occurs in the absence of marked changes in left ventricular size or right ventricular function.</p>","PeriodicalId":83668,"journal":{"name":"Congestive heart failure (Greenwich, Conn.)","volume":"19 1","pages":"11-15"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1751-7133.2012.00302.x","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Congestive heart failure (Greenwich, Conn.)","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/j.1751-7133.2012.00302.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

Abstract

©2012 Wiley Periodicals, Inc.

The aim of this study was to determine the effects of the HeartWare left ventricular assist device (HVAD) (HeartWare International, Inc, Framingham, MA) on hemodynamics, ventricular function, and exercise capacity. Between July 2009 and March 2011, 46 patients with advanced heart failure had implantation of the HVAD. Of these patients, 30 had subsequent assessments for transplantation and these patients formed the study cohort. Thirty patients had assessments at a mean of 201±86 days and 13 went on to have a second assessment at 351±86 days. There were marked improvements in hemodynamics and exercise capacity at both assessments, with significant decreases in right and left heart filling pressures; increases in cardiac index, New York Heart Association class, and peak exercise oxygen consumption; and reduction in pulmonary vascular resistance (all P<.05). Left ventricular end-diastolic and end-systolic dimensions were unchanged at the first assessment, although there was a significant reduction in end-diastolic diameter at the second assessment (P<.01). There were no significant changes in a visual grade of right ventricular function. After up to 1 year of support, the HVAD system results in significant benefits in overall heart failure status, with improved hemodynamics and exercise capacity. This occurs in the absence of marked changes in left ventricular size or right ventricular function.

Abstract Image

血流动力学、超声心动图和运动相关的心脏辅助装置在晚期心力衰竭中的作用
©2012 Wiley期刊公司。本研究的目的是确定HeartWare左心室辅助装置(HVAD) (HeartWare International, Inc., Framingham, MA)对血液动力学、心室功能和运动能力的影响。在2009年7月至2011年3月期间,46例晚期心力衰竭患者植入了HVAD。在这些患者中,有30例患者进行了移植评估,这些患者组成了研究队列。30例患者在平均201±86天进行评估,13例在351±86天进行第二次评估。在两项评估中,血流动力学和运动能力都有显著改善,左右心充盈压力显著降低;心脏指数、纽约心脏协会分级和运动耗氧量峰值增加;肺血管阻力降低(p < 0.05)。左心室舒张末期和收缩末期尺寸在第一次评估时没有变化,尽管在第二次评估时舒张末期直径显著减小(P< 0.01)。右心室功能的视觉分级无明显变化。经过长达1年的支持,HVAD系统对整体心力衰竭状态有显著的益处,血流动力学和运动能力得到改善。这种情况发生在左心室大小或右心室功能没有明显改变的情况下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书