[Assessment of the level of metal ions in the blood of patients after hip resurfacing--preliminary report].

Jacek Markuszewski, Marta Krzyszczuk, Waldemar Woźniak, Paweł Kokoszka, Małgorzata Wierusz-Kozłowska
{"title":"[Assessment of the level of metal ions in the blood of patients after hip resurfacing--preliminary report].","authors":"Jacek Markuszewski,&nbsp;Marta Krzyszczuk,&nbsp;Waldemar Woźniak,&nbsp;Paweł Kokoszka,&nbsp;Małgorzata Wierusz-Kozłowska","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Metal-on-metal bearings characterize lower wear than metal-poly, lower fracture risk than ceramics and they allow for the manufacturing of large diameter heads. The metal ion release from the bearings is the the major concern of these articulations.</p><p><strong>Material: </strong>The study group consisted of 16 patients who underwent hip resurfacing with Durom implant and had minimum 1 year follow-up period. Blood from the patients was collected 4 times: before the surgery, 2, 6 and 12 months postoperatively.</p><p><strong>Methods: </strong>Clinical examination was done according to HHS, Radiographic image was used to measure the cup inclination, evaluation of chromium and cobalt ion blood levels was performed using graphite furnace atomic absorbtion spectrometry (GFAAS).</p><p><strong>Results: </strong>The levels of cobalt and chromium increased postoperatively significantly to decrease slightly at 6 months. At 1 year cobalt levels increased to the similar level like at at 2 months. The chromium level decresed to the values as low as preoperatively. The mean cup inclination angle measured on X-rays was 48 degrees(range 39 degrees - 56 degrees). The mean HHS result was 89.86 (range 64.43 to 98.73). The mean activity level measured with UCLA scale was 6 (range 3-9).</p><p><strong>Conclusions: </strong>The metal ion blond levels increase sigficantly in the period 2-6 months following hip replacement with large diameter metal-on-metal articulation. In further examinations at 1 year post-op ion levels decrease.</p>","PeriodicalId":75702,"journal":{"name":"Chirurgia narzadow ruchu i ortopedia polska","volume":"76 6","pages":"332-5"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chirurgia narzadow ruchu i ortopedia polska","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Metal-on-metal bearings characterize lower wear than metal-poly, lower fracture risk than ceramics and they allow for the manufacturing of large diameter heads. The metal ion release from the bearings is the the major concern of these articulations.

Material: The study group consisted of 16 patients who underwent hip resurfacing with Durom implant and had minimum 1 year follow-up period. Blood from the patients was collected 4 times: before the surgery, 2, 6 and 12 months postoperatively.

Methods: Clinical examination was done according to HHS, Radiographic image was used to measure the cup inclination, evaluation of chromium and cobalt ion blood levels was performed using graphite furnace atomic absorbtion spectrometry (GFAAS).

Results: The levels of cobalt and chromium increased postoperatively significantly to decrease slightly at 6 months. At 1 year cobalt levels increased to the similar level like at at 2 months. The chromium level decresed to the values as low as preoperatively. The mean cup inclination angle measured on X-rays was 48 degrees(range 39 degrees - 56 degrees). The mean HHS result was 89.86 (range 64.43 to 98.73). The mean activity level measured with UCLA scale was 6 (range 3-9).

Conclusions: The metal ion blond levels increase sigficantly in the period 2-6 months following hip replacement with large diameter metal-on-metal articulation. In further examinations at 1 year post-op ion levels decrease.

[髋关节表面置换术后患者血液中金属离子水平的评估——初步报告]。
金属对金属轴承的特点是比金属聚轴承磨损更低,比陶瓷轴承断裂风险更低,并且可以制造大直径的轴承头。从轴承释放的金属离子是这些关节的主要关注点。材料:研究组包括16例使用Durom植入物进行髋关节表面置换的患者,随访期至少1年。分别于术前、术后2个月、6个月、12个月采集患者血液4次。方法:根据HHS进行临床检查,x线片测量杯倾角,石墨炉原子吸收光谱法(GFAAS)测定血中铬、钴离子水平。结果:术后钴、铬水平明显升高,6个月时略有下降。1年后,钴含量增加到与2个月时相似的水平。铬水平降至术前水平。x射线测量的平均杯倾角为48度(范围为39度- 56度)。平均HHS结果为89.86(64.43 ~ 98.73)。UCLA量表测量的平均活动水平为6(范围3-9)。结论:大直径金属对金属关节置换术后2-6个月金属离子水平明显升高。术后1年进一步检查,离子水平下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信