Comparative in vitro dissolution and in vivo bioequivalence of 2 pentoxifylline sustained release formulations.

Arzneimittel-Forschung-Drug Research Pub Date : 2012-07-01 Epub Date: 2012-05-30 DOI:10.1055/s-0032-1312600
P Zakeri-Milani, S Ghanbarzadeh, H Valizadeh
{"title":"Comparative in vitro dissolution and in vivo bioequivalence of 2 pentoxifylline sustained release formulations.","authors":"P Zakeri-Milani,&nbsp;S Ghanbarzadeh,&nbsp;H Valizadeh","doi":"10.1055/s-0032-1312600","DOIUrl":null,"url":null,"abstract":"<p><p>Pentoxifylline is a xanthine derivative that is indicated for the treatment of patients with intermittent claudication on the basis of chronic occlusive arterial disease of the limbs. In the present study, prior to the in vivo study, an in vitro comparative dissolution test was performed by the paddle method for 2 oral sustained release pentoxifylline tablets (400 mg) following the bioequivalence guidance of FDA. Metrics of peak exposure (Cmax) and total exposure to 24 h (AUC24) were compared using a randomized, single oral, open-label, 2-period, 2-sequence, 2 treatments crossover study in 24 healthy male volunteers under fasted conditions. After an overnight fast, the volunteers received 400 mg pentoxifylline and the blood samples were collected over a 24-h period following drug administration. Plasma drug concentrations were measured by a reverse-phase HPLC method with ultraviolet detection. In vitro dissolution tests requirements were met by both formulations. Observed exposure metrics for test and reference products were 140.6±51.5 and 132.6±48.5 ng/ml for Cmax and 986.4±350.7 and 1 035.8±350.3 ng.h/ml for AUC0-24 respectively. The confidence intervals (90%) around ratios (test/reference) of least squares means derived from logarithmic transformed exposure metrics were 0.9912-1.1564% for Cmax and 0.8886-1.0535% for AUC0-24. Therefore it can be concluded that both products are bioequivalent in terms of peak and total exposure and therefore interchangeable.</p>","PeriodicalId":56084,"journal":{"name":"Arzneimittel-Forschung-Drug Research","volume":"62 7","pages":"335-9"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0032-1312600","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arzneimittel-Forschung-Drug Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0032-1312600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/5/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Pentoxifylline is a xanthine derivative that is indicated for the treatment of patients with intermittent claudication on the basis of chronic occlusive arterial disease of the limbs. In the present study, prior to the in vivo study, an in vitro comparative dissolution test was performed by the paddle method for 2 oral sustained release pentoxifylline tablets (400 mg) following the bioequivalence guidance of FDA. Metrics of peak exposure (Cmax) and total exposure to 24 h (AUC24) were compared using a randomized, single oral, open-label, 2-period, 2-sequence, 2 treatments crossover study in 24 healthy male volunteers under fasted conditions. After an overnight fast, the volunteers received 400 mg pentoxifylline and the blood samples were collected over a 24-h period following drug administration. Plasma drug concentrations were measured by a reverse-phase HPLC method with ultraviolet detection. In vitro dissolution tests requirements were met by both formulations. Observed exposure metrics for test and reference products were 140.6±51.5 and 132.6±48.5 ng/ml for Cmax and 986.4±350.7 and 1 035.8±350.3 ng.h/ml for AUC0-24 respectively. The confidence intervals (90%) around ratios (test/reference) of least squares means derived from logarithmic transformed exposure metrics were 0.9912-1.1564% for Cmax and 0.8886-1.0535% for AUC0-24. Therefore it can be concluded that both products are bioequivalent in terms of peak and total exposure and therefore interchangeable.

2己酮茶碱缓释制剂体外溶出度及体内生物等效性比较。
己酮茶碱是一种黄嘌呤衍生物,适用于以肢体慢性动脉闭塞性疾病为基础的间歇性跛行患者。本研究在进行体内研究之前,按照FDA生物等效性指导,采用paddle法对2片口服己酮茶碱缓释片(400 mg)进行体外比较溶出度试验。采用一项随机、单口服、开放标签、2期、2序列、2治疗的交叉研究,比较24名健康男性志愿者在禁食条件下的峰值暴露(Cmax)和24小时总暴露(AUC24)指标。禁食一夜后,志愿者接受400毫克己酮茶碱,并在给药后的24小时内收集血液样本。采用紫外检测反相高效液相色谱法测定血浆药物浓度。两种制剂均满足体外溶出度试验要求。Cmax的暴露量为140.6±51.5和132.6±48.5 ng/ml, AUC0-24的暴露量为986.4±350.7和1035.8±350.3 ng.h/ml。从对数变换暴露指标得出的最小二乘均值的比值(检验/参考)置信区间(90%)为Cmax为0.9912-1.1564%,AUC0-24为0.8886-1.0535%。因此可以得出结论,这两种产品在峰值和总暴露量方面具有生物等效性,因此可以互换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
4-8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信