Steffen Ruchholtz, Carsten Hauk, Ulrike Lewan, Daniel Franz, Christian Kühne, Ralph Zettl
{"title":"Minimally invasive polyaxial locking plate fixation of proximal humeral fractures: a prospective study.","authors":"Steffen Ruchholtz, Carsten Hauk, Ulrike Lewan, Daniel Franz, Christian Kühne, Ralph Zettl","doi":"10.1097/TA.0b013e31823f62e4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The surgical treatment for displaced humeral head fractures overlooks a broad variety of surgical techniques and implant systems. A standard operative procedure has not yet been established. In this article, we report our experience with a second-generation locking plate for the humeral head fracture that is applied in a standardized nine-step minimally invasive surgical technique (MIS).</p><p><strong>Methods: </strong>In a prospective study from May 2008 until November 2009, a cohort of 79 patients with 80 proximal humerus fractures were operated in a MIS procedure using a polyaxial locking plate. Follow-up examination at 6 weeks and 6 months postoperative included radiologic examinations and a clinical outcome analysis by the Constant Score, the Visual Analog Scale for pain, and the Daily Activity Score.</p><p><strong>Results: </strong>The mean patient age was 65.5 years ± 19 years. According to the Neer classification, there were 18 (22.5%) two-part (Neer III), 48 (60%) three-part (Neer IV), and 14 (17.5%) four-part fractures (Neer IV/V). The operation time averaged 65.6 minutes ± 27 minutes. In 13 patients (16.3%), revision was necessary because of procedure-related complications. After 6 months, the Visual Analog Scale for pain was 2.7 ± 1.6 and the Daily Activity Score showed 19.6 ± 6 points. The average age-related Constant Score after 6 months was 67.5 ± 24 points.</p><p><strong>Conclusions: </strong>MIS surgery of displaced humeral head fractures can be performed in all types of humeral head fractures leading to low complication rates and good clinical outcome. A standardized stepwise procedure in fracture reduction and fixation is recommended to achieve reliable good results.</p>","PeriodicalId":48894,"journal":{"name":"Journal of Trauma-Injury Infection and Critical Care","volume":"71 6","pages":"1737-44"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/TA.0b013e31823f62e4","citationCount":"60","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Trauma-Injury Infection and Critical Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/TA.0b013e31823f62e4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 60
Abstract
Background: The surgical treatment for displaced humeral head fractures overlooks a broad variety of surgical techniques and implant systems. A standard operative procedure has not yet been established. In this article, we report our experience with a second-generation locking plate for the humeral head fracture that is applied in a standardized nine-step minimally invasive surgical technique (MIS).
Methods: In a prospective study from May 2008 until November 2009, a cohort of 79 patients with 80 proximal humerus fractures were operated in a MIS procedure using a polyaxial locking plate. Follow-up examination at 6 weeks and 6 months postoperative included radiologic examinations and a clinical outcome analysis by the Constant Score, the Visual Analog Scale for pain, and the Daily Activity Score.
Results: The mean patient age was 65.5 years ± 19 years. According to the Neer classification, there were 18 (22.5%) two-part (Neer III), 48 (60%) three-part (Neer IV), and 14 (17.5%) four-part fractures (Neer IV/V). The operation time averaged 65.6 minutes ± 27 minutes. In 13 patients (16.3%), revision was necessary because of procedure-related complications. After 6 months, the Visual Analog Scale for pain was 2.7 ± 1.6 and the Daily Activity Score showed 19.6 ± 6 points. The average age-related Constant Score after 6 months was 67.5 ± 24 points.
Conclusions: MIS surgery of displaced humeral head fractures can be performed in all types of humeral head fractures leading to low complication rates and good clinical outcome. A standardized stepwise procedure in fracture reduction and fixation is recommended to achieve reliable good results.