C Fu, J Wai, E Lee, C Myden, E Batuyong, C R Hutchison, C Anglin
{"title":"Computer-assisted patellar resection for total knee arthroplasty.","authors":"C Fu, J Wai, E Lee, C Myden, E Batuyong, C R Hutchison, C Anglin","doi":"10.3109/10929088.2011.638399","DOIUrl":null,"url":null,"abstract":"<p><p>Incorrect patellar resection during total knee arthroplasty can lead to anterior knee pain, patellar maltracking, patellofemoral impingement, patellar fracture, component loosening and reduced range of motion. A computer-assisted surgery (CAS) system was developed to improve the accuracy of the patellar cut. Twelve cadaveric knee specimens (6 pairs) were surgically prepared and the patella resected by two senior orthopaedic residents using either a conventional sawguide technique (right knee) or a computer-assisted sawguide technique (left knee). Multiple cuts and measurements were permitted for the conventional technique, to reflect the clinical situation, whereas only a single cut was permitted for the CAS technique. Prior training had been provided on artificial bones for both techniques. Custom marker arrays were mounted on the sawguide and patella. The user positioned the sawguide based on a real-time display that compared the current sawguide plane to the ideal resection. The resulting mediolateral and superoinferior resection angles and central thickness were measured from CT scans of the specimens, relative to the anterior surface of the patella. Both techniques resulted in symmetric cuts (<7°). Repeatability in the mediolateral direction was better for the CAS technique than for the conventional technique (p<0.01). This study demonstrated that computer-assisted patellar resection is a feasible approach that can produce results equal to or better than those obtained with conventional techniques, even when the experimental conditions favor the conventional technique. Improvements in the CAS hardware could further improve the accuracy and usability of the system, resulting in reductions in postoperative complications. Patellar CAS could also serve as a valuable tool for feedback and training.</p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"17 1","pages":"21-8"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2011.638399","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2011.638399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 7
Abstract
Incorrect patellar resection during total knee arthroplasty can lead to anterior knee pain, patellar maltracking, patellofemoral impingement, patellar fracture, component loosening and reduced range of motion. A computer-assisted surgery (CAS) system was developed to improve the accuracy of the patellar cut. Twelve cadaveric knee specimens (6 pairs) were surgically prepared and the patella resected by two senior orthopaedic residents using either a conventional sawguide technique (right knee) or a computer-assisted sawguide technique (left knee). Multiple cuts and measurements were permitted for the conventional technique, to reflect the clinical situation, whereas only a single cut was permitted for the CAS technique. Prior training had been provided on artificial bones for both techniques. Custom marker arrays were mounted on the sawguide and patella. The user positioned the sawguide based on a real-time display that compared the current sawguide plane to the ideal resection. The resulting mediolateral and superoinferior resection angles and central thickness were measured from CT scans of the specimens, relative to the anterior surface of the patella. Both techniques resulted in symmetric cuts (<7°). Repeatability in the mediolateral direction was better for the CAS technique than for the conventional technique (p<0.01). This study demonstrated that computer-assisted patellar resection is a feasible approach that can produce results equal to or better than those obtained with conventional techniques, even when the experimental conditions favor the conventional technique. Improvements in the CAS hardware could further improve the accuracy and usability of the system, resulting in reductions in postoperative complications. Patellar CAS could also serve as a valuable tool for feedback and training.
期刊介绍:
The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.