{"title":"[Evaluation of measurement method of a bacterial sepsis marker, procalcitonin].","authors":"Shoko Adachi, Koichi Nakao","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Procalcitonin (PCT) is a novel biomarker for diagnosis and severity evaluation of bacterial sepsis. PCT measurement methods provided by Wako Pure Chemical Industries, Ltd. include a fully automated chemiluminescent immunoassay system SphereLight Wako and fully automated immunoanalyzer microTASWako i30 for a quantitative measurement, and immunochromatographic assay method, B R A H M S PCT-Q kit. This time, basic performance of SphereLight Wako and microTASWako i30 was evaluated as quantitative determination methods for PCT. The lower limit of detection for the both methods was 0.02 ng/ml. Correlation coefficients of 0.993 to 0.997 indicated good correlation between the two methods. The both methods allow quick and easy measurement of PCT, therefore they are helpful for diagnosis and severity evaluation of bacterial sepsis.</p>","PeriodicalId":74740,"journal":{"name":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","volume":"21 2","pages":"107-9"},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Procalcitonin (PCT) is a novel biomarker for diagnosis and severity evaluation of bacterial sepsis. PCT measurement methods provided by Wako Pure Chemical Industries, Ltd. include a fully automated chemiluminescent immunoassay system SphereLight Wako and fully automated immunoanalyzer microTASWako i30 for a quantitative measurement, and immunochromatographic assay method, B R A H M S PCT-Q kit. This time, basic performance of SphereLight Wako and microTASWako i30 was evaluated as quantitative determination methods for PCT. The lower limit of detection for the both methods was 0.02 ng/ml. Correlation coefficients of 0.993 to 0.997 indicated good correlation between the two methods. The both methods allow quick and easy measurement of PCT, therefore they are helpful for diagnosis and severity evaluation of bacterial sepsis.
降钙素原(PCT)是一种诊断和评估细菌性败血症严重程度的新型生物标志物。Wako Pure Chemical Industries, Ltd.提供的PCT测量方法包括全自动化学发光免疫分析系统SphereLight Wako和用于定量测量的全自动免疫分析仪microTASWako i30,以及免疫层析分析方法,B R a H M S PCT- q试剂盒。本次将SphereLight Wako和microTASWako i30作为PCT的定量检测方法进行基本性能评价,两种方法的检测下限均为0.02 ng/ml。相关系数为0.993 ~ 0.997,表明两种方法相关性较好。两种方法均能快速简便地测定PCT,有助于细菌性脓毒症的诊断和严重程度评价。