Innovations en IRM fonctionnelle cérébrale : marquage de spins artériels et diffusion

H. Raoult , J.-Y. Gauvrit , J. Petr , E. Bannier , E. Le Rumeur , C. Barillot , J.-C. Ferré
{"title":"Innovations en IRM fonctionnelle cérébrale : marquage de spins artériels et diffusion","authors":"H. Raoult ,&nbsp;J.-Y. Gauvrit ,&nbsp;J. Petr ,&nbsp;E. Bannier ,&nbsp;E. Le Rumeur ,&nbsp;C. Barillot ,&nbsp;J.-C. Ferré","doi":"10.1016/j.jradio.2011.04.016","DOIUrl":null,"url":null,"abstract":"<div><p>The standard technique for brain activation functional MRI (fMRI) is the BOLD sequence. Two new techniques have emerged: arterial spin labeling (ASL) MRI and diffusion MRI. Both have the theoretical advantage of more accurately directly demonstrating neuronal activation compared to BOLD imaging, resulting in improved spatial and temporal resolution. ASL is a perfusion sequence using labeled arterial protons as an endogenous perfusion agent. In spite of methodological difficulties, quantitative CBF measurements are possible. ASL is less susceptible to venous contamination than BOLD and more reproducible. Diffusion MRI evaluates neuronal activation at the cellular level with the prospect of excellent spatial resolution. The main limitations for both techniques are the technical difficulties in the acquisition and the low SNR. AS such, ASL is not widely used clinically and diffusion remains in the field of research. However, the increasing availability of 3T MR systems coupled with multi-channel surface coils and improved postprocessing techniques should improve the detection of the brain activation signal. It is thus possible that these techniques could become clinically available either in complement to or as a replacement for BOLD imaging.</p></div>","PeriodicalId":14813,"journal":{"name":"Journal De Radiologie","volume":"92 10","pages":"Pages 878-888"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jradio.2011.04.016","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal De Radiologie","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0221036311003088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The standard technique for brain activation functional MRI (fMRI) is the BOLD sequence. Two new techniques have emerged: arterial spin labeling (ASL) MRI and diffusion MRI. Both have the theoretical advantage of more accurately directly demonstrating neuronal activation compared to BOLD imaging, resulting in improved spatial and temporal resolution. ASL is a perfusion sequence using labeled arterial protons as an endogenous perfusion agent. In spite of methodological difficulties, quantitative CBF measurements are possible. ASL is less susceptible to venous contamination than BOLD and more reproducible. Diffusion MRI evaluates neuronal activation at the cellular level with the prospect of excellent spatial resolution. The main limitations for both techniques are the technical difficulties in the acquisition and the low SNR. AS such, ASL is not widely used clinically and diffusion remains in the field of research. However, the increasing availability of 3T MR systems coupled with multi-channel surface coils and improved postprocessing techniques should improve the detection of the brain activation signal. It is thus possible that these techniques could become clinically available either in complement to or as a replacement for BOLD imaging.

脑功能mri的创新:动脉自旋标记与扩散
脑激活功能MRI (fMRI)的标准技术是BOLD序列。近年来出现了两种新技术:动脉自旋标记(ASL) MRI和弥散MRI。与BOLD成像相比,两者都具有更准确地直接显示神经元激活的理论优势,从而提高了空间和时间分辨率。ASL是一种使用标记动脉质子作为内源性灌注剂的灌注序列。尽管在方法上存在困难,但对脑血流进行定量测量是可能的。ASL比BOLD更不容易受到静脉污染,而且重现性更好。扩散MRI在细胞水平上评估神经元的激活,具有良好的空间分辨率。这两种技术的主要限制是采集技术上的困难和低信噪比。因此,ASL在临床上应用并不广泛,扩散仍处于研究领域。然而,3T MR系统的可用性越来越高,加上多通道表面线圈和改进的后处理技术,应该可以提高对大脑激活信号的检测。因此,这些技术有可能在临床上作为BOLD成像的补充或替代。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal De Radiologie
Journal De Radiologie 医学-核医学
自引率
0.00%
发文量
1
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信