Metal-on-metal total hip arthroplasty - five- to 11-year follow-up.

Vassilios S Nikolaou, Alain Petit, Kevin Debiparshad, Olga L Huk, David J Zukor, John Antoniou
{"title":"Metal-on-metal total hip arthroplasty - five- to 11-year follow-up.","authors":"Vassilios S Nikolaou,&nbsp;Alain Petit,&nbsp;Kevin Debiparshad,&nbsp;Olga L Huk,&nbsp;David J Zukor,&nbsp;John Antoniou","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Metal-on-metal (MoM) total hip arthroplasty (THA) has been introduced in an attempt to reduce the wear rate and the consequent osteolysis around implants. The aim of this study was to present the intermediate to long-term clinical and radiological outcomes and to investigate the metal ion levels in the blood of patients who had undergone primary uncemented MoM THA in our institution. Between July 1997 and November 2003, 166 patients (193 hips), with a mean age of 50 years (range, 18-65 years), underwent primary MoM THA. Clinical data, radiographs, and blood samples were obtained at regular follow-up visits. Cobalt (Co), chromium (Cr), and molybdenum (Mo) ions were measured by inductively coupled plasma-mass spectrometry (ICP-MS) from the patient's whole blood. All patients were prospectively followed for a minimum of 5 years (mean, 7 years; range, 5-11 years). The mean Harris hip score (HHS) and the University of California at Los Angeles (UCLA) activity score at the latest follow-up was 88 ± 11 and 7 ± 1.8 points, respectively. Thirteen hips have been revised. Ten acetabular components had early failure, due to factory manufacturing problems. All other implants have been found stable, with no signs of aseptic loosening. The probability of survival at 11 years, if the hips that were revised due to manufacturing problems were excluded, was 98.4%. The Co and Cr metal ion levels, after increasing significantly during the first 4 to 5 years post-surgery, remained stable, with a tendency to decrease thereafter, but not significantly. During the same follow-up period, Mo ion levels remained stable. In this 5-to-11 year follow-up study of MoM THA patients, excellent survivorship, with low complications rates, was found. Results of longer follow-up studies are necessary to clarify the possible long-term effects of metal ion release.</p>","PeriodicalId":72485,"journal":{"name":"Bulletin of the NYU hospital for joint diseases","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the NYU hospital for joint diseases","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Metal-on-metal (MoM) total hip arthroplasty (THA) has been introduced in an attempt to reduce the wear rate and the consequent osteolysis around implants. The aim of this study was to present the intermediate to long-term clinical and radiological outcomes and to investigate the metal ion levels in the blood of patients who had undergone primary uncemented MoM THA in our institution. Between July 1997 and November 2003, 166 patients (193 hips), with a mean age of 50 years (range, 18-65 years), underwent primary MoM THA. Clinical data, radiographs, and blood samples were obtained at regular follow-up visits. Cobalt (Co), chromium (Cr), and molybdenum (Mo) ions were measured by inductively coupled plasma-mass spectrometry (ICP-MS) from the patient's whole blood. All patients were prospectively followed for a minimum of 5 years (mean, 7 years; range, 5-11 years). The mean Harris hip score (HHS) and the University of California at Los Angeles (UCLA) activity score at the latest follow-up was 88 ± 11 and 7 ± 1.8 points, respectively. Thirteen hips have been revised. Ten acetabular components had early failure, due to factory manufacturing problems. All other implants have been found stable, with no signs of aseptic loosening. The probability of survival at 11 years, if the hips that were revised due to manufacturing problems were excluded, was 98.4%. The Co and Cr metal ion levels, after increasing significantly during the first 4 to 5 years post-surgery, remained stable, with a tendency to decrease thereafter, but not significantly. During the same follow-up period, Mo ion levels remained stable. In this 5-to-11 year follow-up study of MoM THA patients, excellent survivorship, with low complications rates, was found. Results of longer follow-up studies are necessary to clarify the possible long-term effects of metal ion release.

金属对金属全髋关节置换术-随访5 - 11年。
金属对金属(MoM)全髋关节置换术(THA)已被引入,试图减少磨损率和随之而来的植入物周围骨溶解。本研究的目的是介绍中期到长期的临床和放射学结果,并调查在我们机构接受了原发性非胶结MoM THA的患者血液中的金属离子水平。在1997年7月至2003年11月期间,166例患者(193髋),平均年龄50岁(范围18-65岁),接受了原发性MoM THA。在定期随访中获取临床资料、x线片和血液样本。采用电感耦合等离子体质谱法(ICP-MS)测定患者全血中的钴(Co)、铬(Cr)和钼(Mo)离子。所有患者的前瞻性随访时间至少为5年(平均7年;范围:5-11年)。最新随访时Harris髋关节评分(HHS)和UCLA活动评分(UCLA)的平均值分别为88±11分和7±1.8分。13个髋部进行了矫正。由于工厂制造问题,10个髋臼组件早期失效。所有其他植入物均稳定,无无菌性松动迹象。如果排除因制造问题而进行的髋关节手术,11年生存率为98.4%。Co和Cr金属离子水平在术后4 ~ 5年显著升高后保持稳定,此后有下降趋势,但不显著。在同一随访期间,Mo离子水平保持稳定。在这项5- 11年的MoM THA患者随访研究中,发现了良好的生存率和低并发症发生率。需要更长时间的随访研究结果来阐明金属离子释放可能产生的长期影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信